Development of a small OpenPET prototype for in-beam experiments

https://repo.qst.go.jp/records/70326
https://repo.qst.go.jp/records/70326
87e75b64-1c84-4255-b8e5-9278323600b7
Item type 会議発表用資料 / Presentation(1)
公開日 2010-11-15
タイトル
タイトル Development of a small OpenPET prototype for in-beam experiments
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Yoshida, Eiji

× Yoshida, Eiji

WEKO 690595

Yoshida, Eiji

Search repository
et.al

× et.al

WEKO 690596

et.al

Search repository
吉田 英治

× 吉田 英治

WEKO 690597

en 吉田 英治

Search repository
抄録
内容記述タイプ Abstract
内容記述 We have proposed an OpenPET geometry which consists of two axially separated detector rings. The open gap would be suitable for in-beam PET, which is a method for in situ monitoring of charged particle therapy. In the present work, we developed the first prototype of the OpenPET, especially for in-beam experiments using phantoms. The OpenPET prototype was designed with 2 detector rings of 8 detector blocks. Ring diameter was 110 mm and the minimum axial FOV was 99 mm. Distance between detector rings could be controlled. The DOI detector consisted of 784 LGSO crystals which were arranged in a 4-layer design of 14 x 14 arrays, coupled to a 64-ch PS-PMT. Each crystal element was 2.9 x 2.9 x 5 mm3. Front-end circuits were separated from the detector head by 1.2 m coaxial cables. Front-end circuits were set under the detector rings and surrounded by lead and paraffin shields. The system sensitivities were measured from a 22Na point source. The system sensitivity with 15 mm gap width was 6.7 %. On the other hand, the system sensitivity with the open gap was 5.5 %. A count rate performance test was done that utilized an 8 cm cylinder phantom. Maximum count rate of prompt was 28 kcps at 3.5 MBq. The OpenPET prototype has the promise of high sensitivity and sufficient performance for testing in in-beam experiments.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 2010 Nuclear Science Symposium and Medical Imaging Conference
発表年月日
日付 2010-11-06
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:04:13.827171
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3