ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

A preliminary investigation of Cu-62-ATSM tumor hypoxia PET/CT imaging comparing with FDG PET/CT for pancreas cancer

https://repo.qst.go.jp/records/70280
https://repo.qst.go.jp/records/70280
de8c1869-626c-49d0-b9fb-de2042b29f91
Item type 会議発表用資料 / Presentation(1)
公開日 2010-10-20
タイトル
タイトル A preliminary investigation of Cu-62-ATSM tumor hypoxia PET/CT imaging comparing with FDG PET/CT for pancreas cancer
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Yoshikawa, Kyosan

× Yoshikawa, Kyosan

WEKO 690048

Yoshikawa, Kyosan

Search repository
Ohashi, Seiya

× Ohashi, Seiya

WEKO 690049

Ohashi, Seiya

Search repository
Toubaru, Sachiko

× Toubaru, Sachiko

WEKO 690050

Toubaru, Sachiko

Search repository
Hasebe, Mitsuhiko

× Hasebe, Mitsuhiko

WEKO 690051

Hasebe, Mitsuhiko

Search repository
Ishikawa, Hiroyuki

× Ishikawa, Hiroyuki

WEKO 690052

Ishikawa, Hiroyuki

Search repository
Tamura, Katsumi

× Tamura, Katsumi

WEKO 690053

Tamura, Katsumi

Search repository
Shinoto, Makoto

× Shinoto, Makoto

WEKO 690054

Shinoto, Makoto

Search repository
Yamada, Shigeru

× Yamada, Shigeru

WEKO 690055

Yamada, Shigeru

Search repository
Kandatsu, Susumu

× Kandatsu, Susumu

WEKO 690056

Kandatsu, Susumu

Search repository
Shiraishi, Takahiro

× Shiraishi, Takahiro

WEKO 690057

Shiraishi, Takahiro

Search repository
Tanimoto, Katsuyuki

× Tanimoto, Katsuyuki

WEKO 690058

Tanimoto, Katsuyuki

Search repository
Fukumura, Toshimitsu

× Fukumura, Toshimitsu

WEKO 690059

Fukumura, Toshimitsu

Search repository
Saga, Tsuneo

× Saga, Tsuneo

WEKO 690060

Saga, Tsuneo

Search repository
Kamada, Tadashi

× Kamada, Tadashi

WEKO 690061

Kamada, Tadashi

Search repository
吉川 京燦

× 吉川 京燦

WEKO 690062

en 吉川 京燦

Search repository
大橋 靖也

× 大橋 靖也

WEKO 690063

en 大橋 靖也

Search repository
桃原 幸子

× 桃原 幸子

WEKO 690064

en 桃原 幸子

Search repository
長谷部 充彦

× 長谷部 充彦

WEKO 690065

en 長谷部 充彦

Search repository
石川 博之

× 石川 博之

WEKO 690066

en 石川 博之

Search repository
田村 克巳

× 田村 克巳

WEKO 690067

en 田村 克巳

Search repository
篠藤 誠

× 篠藤 誠

WEKO 690068

en 篠藤 誠

Search repository
山田 滋

× 山田 滋

WEKO 690069

en 山田 滋

Search repository
神立 進

× 神立 進

WEKO 690070

en 神立 進

Search repository
白石 貴博

× 白石 貴博

WEKO 690071

en 白石 貴博

Search repository
谷本 克之

× 谷本 克之

WEKO 690072

en 谷本 克之

Search repository
福村 利光

× 福村 利光

WEKO 690073

en 福村 利光

Search repository
佐賀 恒夫

× 佐賀 恒夫

WEKO 690074

en 佐賀 恒夫

Search repository
鎌田 正

× 鎌田 正

WEKO 690075

en 鎌田 正

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose Cu-62labeled diacetyl-bis (N(4)-methylthiosemicarbaone) (Cu-62-ATSM) is a well-knownhypoxic imaging PET tracer. The purpose of this study was to delineate thedifferences in intratumoral uptake and tracer distribution of Cu-62-ATSM andF-18 FDG in patients with pancreas cancer. The comparison of two tracers wasdone before and after carbon ion radiotherapy, and the relationship of traceruptake and patients prognosis was also investigated. Mehod Two male and twofemale (mean age, 62.5 y, range 52-69 y) with pancreas cancer underwent bothCu-62-ATSM and FDG PET/CT before the initiation of carbon ion radiotherapy(CIRT), and the set of PET/CT studies was done one month after termination ofCIRT. Two whole-body PET/CT scanners, Biograph-16 (Siemens) and Aquiduo(Toshiba) were used for data acquisition. Cu-62-ATSM and FDG were administratedapproximately 740 MBq and 370 MBq, respectively. Tumor uptake of each tracerwas analyzed semi-quantitatively by tumor to normal tissue ratio (TNR) forCu-62-ATSM and by standardized absorption value (SUV) for FDG. Result Cu-62-ATSMuptake didnt correlate with FDG uptake before CIRT, but it inverselycorrelated with FDG after CIRT because FDG uptake tended to decrease in allcases. Correlation coefficient of tumor uptake between Cu-62-ATSM and FDGbefore and after CIRT was 0.022 and -0.965, respectively. Average Cu-62-ATSMand FDG uptake before CIRT were 2.9 TNR (range 1.4-3.6 TNR) and 6.7 SUV (range2.9-10.6 SUV), and decreased to 2.7 TNR (range 1.2-4.7 TNR) and 3.8 SUV (range2.6-4.6) after CIRT, respectively. In three out of four patients before CIRTshowed high Cu-62-ATSM uptake that might reflect the trend of them beinghypoxic. A patient showed increase of Cu-62-ATSM uptake after CIRT, but FDGuptake of the same patient didnt increase and almost stable after CIRT. It mightindicate that change of Cu-62-ATSM uptake didnt necessarily correspond tochange of FDG uptake after radiotherapy. Only one patient died after CIRT, andhis Cu-62-ATSM and FDG uptake before therapy were not the highest uptake withinall patients, but both of them were relatively high. Conclusion Cu-62-ATSM andFDG didnt correlate each other before CIRT in pancreas cancer. The change ofCu-62-ATSM uptake didnt necessarily correspond to change of FDG uptake afterCIRT. Cu-62-ATSM and FDG uptake of a patient who died after CIRT were not thehighest uptake, but were relatively high.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 The 2010 EANM Congress
発表年月日
日付 2010-10-13
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:04:46.811695
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3