ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Comparison of Biological Efficiencies of Scanning and Broad Carbon-ion Beams

https://repo.qst.go.jp/records/70164
https://repo.qst.go.jp/records/70164
f3b47e6f-0f82-4993-bf40-f748d70673ea
Item type 会議発表用資料 / Presentation(1)
公開日 2010-06-22
タイトル
タイトル Comparison of Biological Efficiencies of Scanning and Broad Carbon-ion Beams
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Matsumoto, Yoshitaka

× Matsumoto, Yoshitaka

WEKO 688967

Matsumoto, Yoshitaka

Search repository
Inaniwa, Taku

× Inaniwa, Taku

WEKO 688968

Inaniwa, Taku

Search repository
Wada, Mami

× Wada, Mami

WEKO 688969

Wada, Mami

Search repository
Kase, Yuki

× Kase, Yuki

WEKO 688970

Kase, Yuki

Search repository
Satou, Shinji

× Satou, Shinji

WEKO 688971

Satou, Shinji

Search repository
Furukawa, Takuji

× Furukawa, Takuji

WEKO 688972

Furukawa, Takuji

Search repository
Takeshita, Eri

× Takeshita, Eri

WEKO 688973

Takeshita, Eri

Search repository
Himukai, Takeshi

× Himukai, Takeshi

WEKO 688974

Himukai, Takeshi

Search repository
Noda, Kouji

× Noda, Kouji

WEKO 688975

Noda, Kouji

Search repository
Matsufuji, Naruhiro

× Matsufuji, Naruhiro

WEKO 688976

Matsufuji, Naruhiro

Search repository
Furusawa, Yoshiya

× Furusawa, Yoshiya

WEKO 688977

Furusawa, Yoshiya

Search repository
et.al

× et.al

WEKO 688978

et.al

Search repository
松本 孔貴

× 松本 孔貴

WEKO 688979

en 松本 孔貴

Search repository
稲庭 拓

× 稲庭 拓

WEKO 688980

en 稲庭 拓

Search repository
和田 麻美

× 和田 麻美

WEKO 688981

en 和田 麻美

Search repository
佐藤 眞二

× 佐藤 眞二

WEKO 688982

en 佐藤 眞二

Search repository
古川 卓司

× 古川 卓司

WEKO 688983

en 古川 卓司

Search repository
竹下 英里

× 竹下 英里

WEKO 688984

en 竹下 英里

Search repository
日向 猛

× 日向 猛

WEKO 688985

en 日向 猛

Search repository
野田 耕司

× 野田 耕司

WEKO 688986

en 野田 耕司

Search repository
松藤 成弘

× 松藤 成弘

WEKO 688987

en 松藤 成弘

Search repository
古澤 佳也

× 古澤 佳也

WEKO 688988

en 古澤 佳也

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose: More than 5000 patients have been treated with passively generated carbon-ion SOBP beam at HIMAC during 1994 and 2009. Active scanning beam is another method to produce a SOBP, and is used at some facilities such as GSI. There may be some differences in biological effectiveness caused by difference in design of beam distribution, effects from fragmentation, dose-rate at unit area, and so on. The aim of this study is to confirm the difference in the biological effectiveness of scanning beams and passive beams.
Materials and Methods: We used HSG cells that have been used as a standard for RBE measurements of therapeutic ion beams in Japan. The cells were cultured in Eagle-MEM medium supplemented with 10% fetal bovine serum and antibiotics in CO2 incubator. The cells were seeded on 25 mm diameter culture cover slips (1.5x105 cells/slip) in 35 mm dishes or NUNC slide flasks 1.5 days before irradiation. The cells on the slips were transferred into a special made Cell-Stack chamber at defined 4 different depths in the SOBP. Cell exposure was performed with passive and scanning beams at NIRS or scanning beam at GSI. Colony formation assay was applied to obtain cell survival after 14 days post-incubation.
Results: The biological effectiveness in SOBP at proximal (-25 mm), middle (+/- 0 mm), distal (+25 mm) and distal-end (+28 mm) positions, at 10% survival were decreased slightly with the depth at NIRS (passive beam), and it increased slightly at GSI (scanning beam). This may caused the difference in physical dose distribution in SOBP that depends on calculation models used at each facility. Biological dose distribution at distal position normalized to that at proximal position was 1.04 at HIMAC (a ridge-filter #002) and 0.93 at GSI (4 GyE clinical distribution), where as the physical dose distribution was 0.66 and 0.74, respectively. The ratio of biological and physical doses showed a good agreement and the difference were both 12% (= 1.04 / 0.93 or 0.74 / 0.66). Another preliminary experiments with new scanning beam at HIMAC showed better uniformity of biological distribution in the SOBP.
Conclusion: We could confirm no big difference in uniformity of biological distribution between passive and scanning carbon-ion beam. The efficiencies to unit dose of those beams were the same. Dose rate may affects on the killing efficiency, at such high-dose rate.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 PTCOG 49
発表年月日
日付 2010-05-22
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:06:07.138729
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3