ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

In-beam experiment using two OpenPET detectors for carbon beam therapy

https://repo.qst.go.jp/records/70118
https://repo.qst.go.jp/records/70118
1f277cd1-a364-4bbe-b59c-f9d2bf41c566
Item type 会議発表用資料 / Presentation(1)
公開日 2010-05-26
タイトル
タイトル In-beam experiment using two OpenPET detectors for carbon beam therapy
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Nishikido, Fumihiko

× Nishikido, Fumihiko

WEKO 688517

Nishikido, Fumihiko

Search repository
Yazaki, Yujiro

× Yazaki, Yujiro

WEKO 688518

Yazaki, Yujiro

Search repository
Osada, Hiroto

× Osada, Hiroto

WEKO 688519

Osada, Hiroto

Search repository
Mitsuhashi, Takayuki

× Mitsuhashi, Takayuki

WEKO 688520

Mitsuhashi, Takayuki

Search repository
Inadama, Naoko

× Inadama, Naoko

WEKO 688521

Inadama, Naoko

Search repository
Yoshida, Eiji

× Yoshida, Eiji

WEKO 688522

Yoshida, Eiji

Search repository
Inaniwa, Taku

× Inaniwa, Taku

WEKO 688523

Inaniwa, Taku

Search repository
Satou, Shinji

× Satou, Shinji

WEKO 688524

Satou, Shinji

Search repository
Murayama, Hideo

× Murayama, Hideo

WEKO 688525

Murayama, Hideo

Search repository
Yamaya, Taiga

× Yamaya, Taiga

WEKO 688526

Yamaya, Taiga

Search repository
錦戸 文彦

× 錦戸 文彦

WEKO 688527

en 錦戸 文彦

Search repository
矢崎 祐次郎

× 矢崎 祐次郎

WEKO 688528

en 矢崎 祐次郎

Search repository
長田 拓人

× 長田 拓人

WEKO 688529

en 長田 拓人

Search repository
三橋 隆之

× 三橋 隆之

WEKO 688530

en 三橋 隆之

Search repository
稲玉 直子

× 稲玉 直子

WEKO 688531

en 稲玉 直子

Search repository
吉田 英治

× 吉田 英治

WEKO 688532

en 吉田 英治

Search repository
稲庭 拓

× 稲庭 拓

WEKO 688533

en 稲庭 拓

Search repository
佐藤 眞二

× 佐藤 眞二

WEKO 688534

en 佐藤 眞二

Search repository
村山 秀雄

× 村山 秀雄

WEKO 688535

en 村山 秀雄

Search repository
山谷 泰賀

× 山谷 泰賀

WEKO 688536

en 山谷 泰賀

Search repository
抄録
内容記述タイプ Abstract
内容記述 1. Propose
We have proposed the "OpenPET" geometry which consists of two detector rings separated axially. The OpenPET is suitable for use as in-beam PET in carbon ion therapy due to the open space between the separated detector rings. Although the primary carbon ions do not enter into the PET detector in the OpenPET, light fragment ions from a target can enter into the detectors. Therefore the detector components, especially scintillators, are strongly activated and our usual measurement system could not be work normally due to high background from activated nuclei. In previous experiments, we applied some improvements to the measurement system and succeeded the off-beam measurement under high count rate environments after heavy ion irradiation. Then, we performed in-beam experiments using two OpenPET detector. We will report results about the in-beam experiment in this presentation.
\n2. Methods
The experiments were performed using 12C beam in the Heavy Ion Medical Accelerator in Chiba (HIMAC) at the National Institute of Radiological Sciences. The energy and intensity of the carbon beam were 290MeV/u and 10E8-10E9 pps. Carbon ions entered into a water phantom through an ionization chamber used as a beam intensity monitor. All of the primary carbon ions were stopped in the water phantom. The OpenPET detector consists of a 14x14x4 LGSO (Hitachi Chemical Co., Ltd., Japan) crystal array with the optimized reflector arrangement and a 64ch PS-PMT (H8500, Hamamatsu Photonics K.K., Japan). The OpenPET detector were positioned 30cm apart from the backside of the water phantom at an angle of 30 degree. A coincidence detector which consisted of a 14x14x4 LGSO crystal array and a PS-PMT was positioned at the opposite side of the water phantom.
\n3. Results
The sufficient crystal identification performance as a PET detector can be achieved in the center part of the crystal array. Because pile up events and baseline variance during intervals of beam spills were not corrected, crystal identification performances of a part of the crystals were degraded. These problems can be resolved by using a pulse sampling method and we will apply the method to the OpenPET detector in future experiments.
\n4. Conclusion
We are developing the OpenPET detector for heavy ion therapy. The in-beam experiment using the pair of the OpenPET detectors were performed in HIMAC. We conclude that the OpenPET detector worked sufficiently as a PET detector under the in-beam environment.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 PTCOG49
発表年月日
日付 2010-05-22
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:06:37.860619
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3