ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Feasibility study of entire whole-body PET scanners based on the OpenPET geometry

https://repo.qst.go.jp/records/69930
https://repo.qst.go.jp/records/69930
81e2ace3-f061-4988-84d2-1ef699e9fa25
Item type 会議発表用資料 / Presentation(1)
公開日 2009-11-09
タイトル
タイトル Feasibility study of entire whole-body PET scanners based on the OpenPET geometry
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Yoshida, Eiji

× Yoshida, Eiji

WEKO 686639

Yoshida, Eiji

Search repository
et.al

× et.al

WEKO 686640

et.al

Search repository
吉田 英治

× 吉田 英治

WEKO 686641

en 吉田 英治

Search repository
抄録
内容記述タイプ Abstract
内容記述 A conventional PET scanner has a 15-25 cm axial field-of-view (FOV) and images a whole body using about six bed positions. An OpenPET geometry can extend the axial FOV with a limited number of detectors. The entire whole-body PET scanner must be able to process a huge amount of data, effectively. In this work, we study feasibility of the fully 3D entire whole-body PET scanner using the GATE simulation. The OpenPET has 12 block detector rings with the ring diameter of 840 mm and each block detector ring consists of 48 DOI (depth-of-interaction) detectors. The OpenPET has the axial length of 895.95 mm with five parts of 58.95 mm open gaps. The OpenPET has higher single data loss than a conventional PET scanner at grouping circuits. NECR of the OpenPET decreases by single data loss. But, single data loss is improved by separating the axially arranged detector into two parts. Also, multiple coincidences are found to be important for the entire whole-body PET scanner. The entire whole-body PET scanner with the OpenPET geometry promises to provide a large axial FOV with the open space and to have sufficient performance values. But, single data loss at the grouping circuit and multiple coincidences are limited to the peak NECR for the entire whole-body PET canner.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 IEEE Nuclear Science Symposium and Medical Imaging Conference
発表年月日
日付 2009-10-31
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:08:47.589738
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3