ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Advancement in Hypofractionation of Carbon Ion Radiotherapy for Prostate Cancer

https://repo.qst.go.jp/records/69923
https://repo.qst.go.jp/records/69923
dc94e702-2bc1-4b6b-b831-65b426bc454f
Item type 会議発表用資料 / Presentation(1)
公開日 2009-11-09
タイトル
タイトル Advancement in Hypofractionation of Carbon Ion Radiotherapy for Prostate Cancer
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Tsuji, Hiroshi

× Tsuji, Hiroshi

WEKO 686573

Tsuji, Hiroshi

Search repository
Okada, Tohru

× Okada, Tohru

WEKO 686574

Okada, Tohru

Search repository
Sugahara, Shinji

× Sugahara, Shinji

WEKO 686575

Sugahara, Shinji

Search repository
Kato, Hiroyuki

× Kato, Hiroyuki

WEKO 686576

Kato, Hiroyuki

Search repository
Ishikawa, Hitoshi

× Ishikawa, Hitoshi

WEKO 686577

Ishikawa, Hitoshi

Search repository
Kamada, Tadashi

× Kamada, Tadashi

WEKO 686578

Kamada, Tadashi

Search repository
Mizoe, Junetsu

× Mizoe, Junetsu

WEKO 686579

Mizoe, Junetsu

Search repository
Kanai, Tatsuaki

× Kanai, Tatsuaki

WEKO 686580

Kanai, Tatsuaki

Search repository
Tsujii, Hirohiko

× Tsujii, Hirohiko

WEKO 686581

Tsujii, Hirohiko

Search repository
辻 比呂志

× 辻 比呂志

WEKO 686582

en 辻 比呂志

Search repository
岡田 徹

× 岡田 徹

WEKO 686583

en 岡田 徹

Search repository
菅原 信二

× 菅原 信二

WEKO 686584

en 菅原 信二

Search repository
加藤 弘之

× 加藤 弘之

WEKO 686585

en 加藤 弘之

Search repository
石川 仁

× 石川 仁

WEKO 686586

en 石川 仁

Search repository
鎌田 正

× 鎌田 正

WEKO 686587

en 鎌田 正

Search repository
溝江 純悦

× 溝江 純悦

WEKO 686588

en 溝江 純悦

Search repository
金井 達明

× 金井 達明

WEKO 686589

en 金井 達明

Search repository
辻井 博彦

× 辻井 博彦

WEKO 686590

en 辻井 博彦

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose: To assess the effect of alteration in dose fractionation on late radiation toxicity in prostate cancer patients treated with conformal carbon ion radiotherapy (C-ion RT)
Methods and Materials: Applied carbon ion dose in 20fractions were either of 66.0Gy RBE or 63.0Gy RBE and that in 16fractions was 57.6Gy RBE.. Seventy hundreds and forty prostate cancer patients who received the C-ion RT of 20fractions/5weeks or 16fractions/4weeks were analyzed in regard to late radiation toxicity. In addition, biochemical relapse free and survival rates in patient subgroup treated with each dose-fractionation were analyzed.
Results: No grade 3 or worse toxicities were observed either in the rectum or genitourinary system (GU) and the incidences of grade 2 rectum and GU toxicity in the 664 patients followed up more than 12 months were 1.9% and 4.8%, respectively. The incidence of late GU toxicity in patients treated with 16 fractions (1.5%) was lower than that of 20fractions (6.2%). Dose dependency was observed between 66.0Gy RBE and 63.0Gy RBE in patients received C-ion RT of 20fraction. Overall biochemical relapse free rate (BRF) at 5 years for 740 patients was 90.2%. Gleason's score, T-stage, and initial PSA were significant prognostic factors for BRF, and T-stage was also a significant prognostic factor for overall survival rate. The 5 year-BRF of the patients treated with 16 fractions C-ion RT (87.5%) was comparable to that of 20 fractions (90.5%). Overall and cause-specific survival rates at 5 year of the entire group were 95.4% and 98.8%, respectively.
Conclusion: C-ion RT of 57.6Gy RBE in 16 fractions could offer even lower incidence of GU toxicity and comparable BRF compared to that of 63.0 or 66.0Gy RBE in 20fractions. Advancement in hypofractionation could be safely achieved in the C-ion RT for prostate cancer.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 51st ASTRO Annual Meeting
発表年月日
日付 2009-11-05
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:08:52.340304
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3