ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Practical performance evaluation of a commercial small animal SPECT system with a single-pinhole or 5-hole collimator

https://repo.qst.go.jp/records/69916
https://repo.qst.go.jp/records/69916
3f1ec97e-7aa5-4040-accb-c19ce746be46
Item type 会議発表用資料 / Presentation(1)
公開日 2009-10-26
タイトル
タイトル Practical performance evaluation of a commercial small animal SPECT system with a single-pinhole or 5-hole collimator
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Inubushi, Masayuki

× Inubushi, Masayuki

WEKO 686510

Inubushi, Masayuki

Search repository
Shidahara, Miho

× Shidahara, Miho

WEKO 686511

Shidahara, Miho

Search repository
Murai, Chika

× Murai, Chika

WEKO 686512

Murai, Chika

Search repository
Tsuji, Atsushi

× Tsuji, Atsushi

WEKO 686513

Tsuji, Atsushi

Search repository
Koizumi, Mitsuru

× Koizumi, Mitsuru

WEKO 686514

Koizumi, Mitsuru

Search repository
Kanno, Iwao

× Kanno, Iwao

WEKO 686515

Kanno, Iwao

Search repository
Saga, Tsuneo

× Saga, Tsuneo

WEKO 686516

Saga, Tsuneo

Search repository
犬伏 正幸

× 犬伏 正幸

WEKO 686517

en 犬伏 正幸

Search repository
志田原 美保

× 志田原 美保

WEKO 686518

en 志田原 美保

Search repository
村井 知佳

× 村井 知佳

WEKO 686519

en 村井 知佳

Search repository
辻 厚至

× 辻 厚至

WEKO 686520

en 辻 厚至

Search repository
小泉 満

× 小泉 満

WEKO 686521

en 小泉 満

Search repository
菅野 巖

× 菅野 巖

WEKO 686522

en 菅野 巖

Search repository
佐賀 恒夫

× 佐賀 恒夫

WEKO 686523

en 佐賀 恒夫

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose: From the viewpoint of practical use, we evaluated the basic performance of a commercial high-resolution small animal SPECT system FX(SPECT/CT) (Gamma Medica-Ideas, CA) In our system, a single-pinhole or 5-hole collimator, which consists of 1mm diameter apertures, can be mounted on a 12 x 12cm NaI(Tl) scintillation detector.
Methods: For evaluation of spatial resolution, sensitivity and effective FOV, a line source, a point source and a cylindrical phantom (1.6cm diameter) filled with 99mTcO4- solution were scanned with various rotation of radius (ROR) from 2.5cm to 8.0cm. The sensitivity, E [cps/MBq], using a point source located at the center of rotation was calculated by the division of measured total counts in the projection and its known activity. For resolution FWHM was calculated by fitting the line source image with Gaussian function. The axial length of cylindrical phantom, which preserve less than 10% bias compared with averaged counts in 1cm diam. circular region of interest (ROI) at the central slice, was regarded as effective FOV.
Results: The relationship between sensitivity (y) and ROR (x) was y = 175.9x^(-1.97), y = 1641x^(-2.04) for single- and 5-hole collimator, respectively. The relationship between resolution (y) and ROR (x) was y = 0.13x+0.49, y = 0.19x+0.29, respectively. Effective FOV (y) of single-hole collimator (y = 1.2x-1.3) resulted in quite different from that of 5-hole collimator (y = 0.42x-0.45) due to the amount of overlapping in projection data.
Conclusions: We evaluated the basic performance of the pinhole SPECT system, which did not depend only on detector system but also on ROR and the type of collimator. For its practical use, therefore, physical setting such as ROR and collimator should be carefully optimized for research purposes.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 Annual Congress of the European Association of Nuclear Medicine 2009
発表年月日
日付 2009-10-14
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:08:57.504508
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3