ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Verification of cosmic radiation dose rates at the summit of Mt.Fuji

https://repo.qst.go.jp/records/69899
https://repo.qst.go.jp/records/69899
e0771750-331b-46d7-8ce3-0bea7c915aae
Item type 会議発表用資料 / Presentation(1)
公開日 2009-10-19
タイトル
タイトル Verification of cosmic radiation dose rates at the summit of Mt.Fuji
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Yasuda, Hiroshi

× Yasuda, Hiroshi

WEKO 686277

Yasuda, Hiroshi

Search repository
Yajima, Kazuaki

× Yajima, Kazuaki

WEKO 686278

Yajima, Kazuaki

Search repository
保田 浩志

× 保田 浩志

WEKO 686279

en 保田 浩志

Search repository
矢島 千秋

× 矢島 千秋

WEKO 686280

en 矢島 千秋

Search repository
抄録
内容記述タイプ Abstract
内容記述 From the 2007 fiscal year, the National Institute of Radiological Sciences (NIRS) has supported the assessment of cosmic radiation exposure of aircraft crew working for Japanese airline companies, according to the guideline settled on at April 2006 by the Radiation Council of the Japanese government. The radiation doses of crew are estimated using a recently developed program for calculation of aviation route doses JISCARD EX which has employed a PHITS-based analytical model PARMA. For reliable assessments, precision of calculated doses are desirably to be verified by measurements at high altitude..
We thus measured cosmic radiation at the summit of Mt. Fuji (3,776m in altitude), the highest mountain in Japan, for comparison of dose rates with model calculations. Measurements during the summer from July to August were carried out repeatedly three times on 2007, 2008 and 2009 in a building of the Mt.Fuji weather station using selected radiation monitors such as several types of neutron monitor, phoswich scintillation detectors and an ionizing chamber coupled each with an exclusive data logger.
As results, ambient dose equivalent rates measured for the solar minimum agreed well with model calculations. Possible systematic errors attributing to the uncertain spectra of high-energy cosmic-ray components are discussed according to separated signals of the scintillation detector.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 11th Neutron and Ion Dosimetry Symposium (NEUDOS-11)
発表年月日
日付 2009-10-16
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:09:09.332689
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3