MEASUREMENT OF IN-AIR AND IN-WATER ABSORBED DOSES AND QUALITY FACTORS OUTSIDE OF THE IRRADIATION FIELD IN PASSIVE CARBON-ION RADIOTHERAPY

https://repo.qst.go.jp/records/69896
https://repo.qst.go.jp/records/69896
8f506772-07db-4a6b-80d4-5de843d66249
Item type 会議発表用資料 / Presentation(1)
公開日 2009-10-19
タイトル
タイトル MEASUREMENT OF IN-AIR AND IN-WATER ABSORBED DOSES AND QUALITY FACTORS OUTSIDE OF THE IRRADIATION FIELD IN PASSIVE CARBON-ION RADIOTHERAPY
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Yonai, Shunsuke

× Yonai, Shunsuke

WEKO 686255

Yonai, Shunsuke

Search repository
Kase, Yuuki

× Kase, Yuuki

WEKO 686256

Kase, Yuuki

Search repository
Matsufuji, Naruhiro

× Matsufuji, Naruhiro

WEKO 686257

Matsufuji, Naruhiro

Search repository
Kanai, Tatsuaki

× Kanai, Tatsuaki

WEKO 686258

Kanai, Tatsuaki

Search repository
米内 俊祐

× 米内 俊祐

WEKO 686259

en 米内 俊祐

Search repository
加瀬 優紀

× 加瀬 優紀

WEKO 686260

en 加瀬 優紀

Search repository
松藤 成弘

× 松藤 成弘

WEKO 686261

en 松藤 成弘

Search repository
金井 達明

× 金井 達明

WEKO 686262

en 金井 達明

Search repository
抄録
内容記述タイプ Abstract
内容記述 The National Institute of Radiological Sciences (NIRS) has extensively studied passive carbon-ion radiotherapy for cancer treatment with some positive outcomes. These successful results allow the patients to live for a longer time and younger patients to receive the radiotherapy. The incidence of secondary malignance as a result of the radiotherapy in these patients is of great concern to us. Especially, the assessment of the secondary neutrons inevitably produced within the patient and beam line devices in the carbon-ion radiotherapy is very important due to the potency of their biological effect. Our previous study showed that the secondary neutron exposure in normal tissues far from the target volume in carbon-ion radiotherapy is lower than that in proton radiotherapy, and is equal to or less than that in photon radiotherapy based on the measurement of the ambient dose equivalents at the patient position. [1] However, it is considered to be non-negligible in the estimation of the secondary cancer risk. Distributions of the absorbed dose and the biological effectiveness in the patient are required for assessing the risk. Such investigations are often performed using Monte Carlo calculations,[2] because it is very difficult to obtain them experimentally. However, the experimental verification of the calculations has to be done for the accurate assessment. In this study, in-air and in-water lineal energy distributions were measured by using a commercial tissue equivalent proportional counter (TEPC) at Heavy Ion Medical Accelerator in Chiba (HIMAC) treatment room. Based on the lineal energy distributions, we could obtain the in-air and in-water absorbed doses and quality factors. TEPC dosimetry can not discriminate the information of neutrons and other radiations when using TEPC only, but can provide biologically relevant information. These measured data should be useful for the secondary cancer risk assessment based on experimental data and the verification of Monte Carlo calculation.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 NEUDOS-11
発表年月日
日付 2009-10-16
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:09:11.543945
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3