COMPARISON OF MEASESURED AND CALCULATED IN-AIR SECONDARY NEUTRONS IN PASSIVE CARBON-ION RADIOTHERAPY

https://repo.qst.go.jp/records/69895
https://repo.qst.go.jp/records/69895
ef6b2800-4fda-4af6-a78a-108f60f8475f
Item type 会議発表用資料 / Presentation(1)
公開日 2009-10-19
タイトル
タイトル COMPARISON OF MEASESURED AND CALCULATED IN-AIR SECONDARY NEUTRONS IN PASSIVE CARBON-ION RADIOTHERAPY
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Yonai, Shunsuke

× Yonai, Shunsuke

WEKO 686248

Yonai, Shunsuke

Search repository
Matsufuji, Naruhiro

× Matsufuji, Naruhiro

WEKO 686249

Matsufuji, Naruhiro

Search repository
Kanai, Tatsuaki

× Kanai, Tatsuaki

WEKO 686250

Kanai, Tatsuaki

Search repository
et.al

× et.al

WEKO 686251

et.al

Search repository
米内 俊祐

× 米内 俊祐

WEKO 686252

en 米内 俊祐

Search repository
松藤 成弘

× 松藤 成弘

WEKO 686253

en 松藤 成弘

Search repository
金井 達明

× 金井 達明

WEKO 686254

en 金井 達明

Search repository
抄録
内容記述タイプ Abstract
内容記述 In proton and carbon-ion radiotherapies, undesired radiation exposure in normal tissues around a treatment volume is less than that in the conventional radiotherapies because of the physical property known as the Bragg peak. In addition, carbon-ion beams can reduce the undesired exposure laterally because of less scattering power. Such exposure is always considered in a treatment planning. However, undesired exposure far from the treatment volume cannot be considered in the treatment planning, because it is caused by secondary radiation as well as leakage primary particles. Though this exposure is considerably lower than that near the treatment volume, it is not negligible to estimate the risk of secondary cancer especially for the young patients. In particular, the assessment of the secondary neutrons that inevitably produced within the patient and beam line devices is very important due to the potency of their biological effect. As the first step in assessing the risk, we have measured spatial and energy distributions of the neutrons and neutron ambient dose equivalents using Bonner sphere system (BSS) [1] and a rem meter, WENDI-II [2] at Heavy Ion Medical Accelerator in Chiba (HIMAC) treatment room. On the other hand, the distributions of the absorbed dose and the biological effectiveness in phantom are required to assess the risk, and Monte Carlo calculation plays a key role due to a difficulty of the measurement. In this study, measured in-air neutrons at the patient position (in the direction orthogonal to the beam axis) in passive carbon-ion radiotherapy were compared with those calculated with the Monte Carlo code, PHITS to verify the accuracy. Our calculations underestimated epithermal neutrons resulting from scattering by the beam line devices due to the lack of the calculational geometry modeling, but could reproduce the measured ambient dose equivalents well because they were dominated by neutrons energies above 0.1 MeV.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 NEUDOS-11
発表年月日
日付 2009-10-16
日付タイプ Issued
戻る
0
views
See details
Views