  1. 学会発表・講演等
  2. ポスター発表

The influence of the fragment particles from carbon beam on an OpenPET detector as in-beam PET for heavy ion therapy

https://repo.qst.go.jp/records/69882
https://repo.qst.go.jp/records/69882
b44e9135-2285-4db7-82b3-80ca3d13d911
Item type 会議発表用資料 / Presentation(1)
公開日 2009-10-06
タイトル
タイトル The influence of the fragment particles from carbon beam on an OpenPET detector as in-beam PET for heavy ion therapy
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Nishikido, Fumihiko

× Nishikido, Fumihiko

WEKO 686087

Nishikido, Fumihiko

Search repository
Yazaki, Yujiro

× Yazaki, Yujiro

WEKO 686088

Yazaki, Yujiro

Search repository
Osada, Hiroto

× Osada, Hiroto

WEKO 686089

Osada, Hiroto

Search repository
Inadama, Naoko

× Inadama, Naoko

WEKO 686090

Inadama, Naoko

Search repository
Inaniwa, Taku

× Inaniwa, Taku

WEKO 686091

Inaniwa, Taku

Search repository
Satou, Shinji

× Satou, Shinji

WEKO 686092

Satou, Shinji

Search repository
Yoshida, Eiji

× Yoshida, Eiji

WEKO 686093

Yoshida, Eiji

Search repository
Yamaya, Taiga

× Yamaya, Taiga

WEKO 686094

Yamaya, Taiga

Search repository
Murayama, Hideo

× Murayama, Hideo

WEKO 686095

Murayama, Hideo

Search repository
錦戸 文彦

× 錦戸 文彦

WEKO 686096

en 錦戸 文彦

Search repository
矢崎 祐次郎

× 矢崎 祐次郎

WEKO 686097

en 矢崎 祐次郎

Search repository
長田 拓人

× 長田 拓人

WEKO 686098

en 長田 拓人

Search repository
稲玉 直子

× 稲玉 直子

WEKO 686099

en 稲玉 直子

Search repository
稲庭 拓

× 稲庭 拓

WEKO 686100

en 稲庭 拓

Search repository
佐藤 眞二

× 佐藤 眞二

WEKO 686101

en 佐藤 眞二

Search repository
吉田 英治

× 吉田 英治

WEKO 686102

en 吉田 英治

Search repository
山谷 泰賀

× 山谷 泰賀

WEKO 686103

en 山谷 泰賀

Search repository
村山 秀雄

× 村山 秀雄

WEKO 686104

en 村山 秀雄

Search repository
抄録
内容記述タイプ Abstract
内容記述 1. Background
We have proposed the "OpenPET" geometry which consists of two detector rings separated axially. The OpenPET is suitable for use as in-beam PET in heavy ion therapy due to the open space between the separated detector rings. Annihilation gamma rays from irradiated volumes enter obliquely into OpenPET detectors. Therefore, detectors which can measure depth of interaction (DOI) are required to reduce parallax error. Since the DOI detectors need to identify the large number of crystals in proportion to the number of depth layers, the crystal identification performance is possible to deteriorate under heavy ion irradiation. In this presentation, we report the results of experiments about the influences of heavy ion irradiation, especially fragment particles, on the OpenPET detectors.
\n2. Material and methods
The experiments were performed using carbon beam in the Heavy Ion Medical Accelerator in Chiba (HIMAC) at the National Institute of Radiological Sciences. The energy and intensity of the carbon beam were 290MeV/u and 108-109 pps. Carbon ions entered to a water phantom through an ionization chamber used as a beam intensity monitor. All of the primary carbon ions were stopped in the water phantom. First, to compare the influences of fragment particles on various scintillation materials, same size crystals of BGO, LuAG, LYSO and YSO were irradiated by 3.0E+8 pps carbon beam and measured with a single channel PMT. Next, the influence of fragment particles on the DOI detector was studied. The DOI detector which consisted of a 8x8x4 LGSO crystal array with the optimized reflector arrangement and a 64ch position sensitive PMT. The scintillator and the OpenPET detector were positioned 30cm apart from the backside of the water phantom at an angle of 30 degree.
\n3. Results
After heavy ion irradiation, all of the scintillators were activated due to incidence of the fragment particles from the water phantom. The activation of the scintillators is lead to increase of count rate and degraded the performance of the DOI detector. From the comparison of the results for the scintillators, the increase of count rate depends on the effective atomic numbers. We conclude that lutetium doped scintillators are suitable in terms of the activation and detector performances previously studied. The DOI detector positioned in the OpenPET geometry were also affected by the fragment particles even though it was not in the line of the primary beam. However, we obtained sufficient detector performance as a PET detector by optimizing to an environment of heavy ion irradiation.
\n4. Conclusion
We studied responses of the OpenPET detector under heavy ion therapy. The influences of the activation by the fragment particles were measured for the various scintillators. We obtained sufficient detector performance as a PET detector by optimizing to the environment of heavy ion irradiation.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 PTCOG48
発表年月日
日付 2009-10-03
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:09:21.062226
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3