ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Multiple charged carbon-ion production for the heavy ion therapy

https://repo.qst.go.jp/records/69880
https://repo.qst.go.jp/records/69880
e4baad17-06e9-4765-a081-bd3152219533
Item type 会議発表用資料 / Presentation(1)
公開日 2009-10-06
タイトル
タイトル Multiple charged carbon-ion production for the heavy ion therapy
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kitagawa, Atsushi

× Kitagawa, Atsushi

WEKO 686070

Kitagawa, Atsushi

Search repository
北川 敦志

× 北川 敦志

WEKO 686071

en 北川 敦志

Search repository
抄録
内容記述タイプ Abstract
内容記述 For almost components of the facility, it's not so different that the accelerated beam is carbon or not. However, for ion sources, the production of carbon ions is harder effort than other ion species. An ECR ion source has been developed and utilized to produce carbon ions for the clinical treatment, because its lifetime is longer than other types of ion sources. The performance of the ECR ion source is degraded due to carbon deposition on 1) an electric insulator, 2) the waveguide, 3) the plasma-chamber wall, and most of the other parts. The deposition on 3) is normally unavoidable. The record intensity has reached 430 microAe for C4+ under good conditions, just after a cleaning; however, the beam intensity decreases to about 300 microAe caused by rapid carbon deposition after several days. As a result, although the intensity was slightly decreasing, the source was able to produce about 240 microAe, even 4 years after without maintenance. The wall condition varied according to the contaminated ion species or the operation for different ion species before. Since the variation often causes instability or poor reproducibility, it's better to keep two ion sources in order to frequently supply different ion species, especially.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 第48回Perticle Therapy Co-Operative Group
発表年月日
日付 2009-10-03
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:09:22.438596
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3