Dose audit using a glass dosimeter for Radiation Therapy Facilities in East-Asian Countries

https://repo.qst.go.jp/records/69849
https://repo.qst.go.jp/records/69849
0ed4b335-0ba0-4160-81ba-99182aa8cd2f
Item type 会議発表用資料 / Presentation(1)
公開日 2009-09-15
タイトル
タイトル Dose audit using a glass dosimeter for Radiation Therapy Facilities in East-Asian Countries
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Mizuno, Hideyuki

× Mizuno, Hideyuki

WEKO 685768

Mizuno, Hideyuki

Search repository
et.al

× et.al

WEKO 685769

et.al

Search repository
水野 秀之

× 水野 秀之

WEKO 685770

en 水野 秀之

Search repository
抄録
内容記述タイプ Abstract
内容記述 A dose audit using a photoluminescent glass dosimeter was conducted in radiation therapy facilities in a number of East-Asian countries. The audit was performed for the reference condition of linac X-ray beams, which was a 10x10 cm2 field and a 10cm depth with a SSD of 90 cm. Eight facilities from 5 countries, China, Korea, Indonesia, Viet Nam and the Philippines, participated in this audit. The ratios of deviation between the user-stated dose and the NIRS measured dose were analyzed. Among 24 X-rays beams measured from 6 to 20MV, 22 beams were within optimum levels (3%) and 1 beam was out of the optimum level but within the tolerance level (5%). However, 1 beam exceeded the tolerance level. The standard deviation of the ratios of deviation was 1.4%. A thorough and lengthy investigation was performed regarding this beam, which was observed to have a large rate of deviation (+6.1%). Finally, the cause became clear when it was deter-mined that an incorrect pressure value in the calibration of a monitoring unit had been used. This event shows the impor-tance of external audit in radiation therapy.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 WORLD CONGRESS 2009
発表年月日
日付 2009-09-12
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:09:43.755601
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3