WEKO3
アイテム
Dynamic splitting of Gaussian pencil beams in heterogeneity-correction algorithms for radiotherapy with heavy charged particles
https://repo.qst.go.jp/records/69819
https://repo.qst.go.jp/records/69819d4248a3c-fb73-43e0-8b11-a44ffa6ac558
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2009-08-02 | |||||
タイトル | ||||||
タイトル | Dynamic splitting of Gaussian pencil beams in heterogeneity-correction algorithms for radiotherapy with heavy charged particles | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Kanematsu, Nobuyuki
× Kanematsu, Nobuyuki× Komori, Masataka× Yonai, Shunsuke× Ishizaki, Azusa× 兼松 伸幸× 小森 雅孝× 米内 俊祐× 石崎 梓 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Purpose: To develop an algorithm to resolve intrinsic problems with dose calculations using pencil beams when particles involved in each beam are overreaching a lateral density interface or when they are detouring in a laterally heterogeneous medium. Method and Materials: A finding on a Gaussian distribution, such that it can be approximately decomposed into multiple narrower, shifted, and scaled ones, was applied to dynamic splitting of pencil beams implemented in a dose calculation algorithm for proton and ion beams. The method was tested in an experiment with a range-compensated carbon-ion beam. Its effectiveness and efficiency were evaluated for carbon-ion and proton beams in a heterogeneous phantom model. Results: The splitting dose calculation reproduced the detour effect observed in the experiment, which amounted to about 10% at a maximum or as large as the lateral particle-disequilibrium effect. The proton-beam dose generally showed large scattering effects including the overreach and detour effects. The overall computational times were 9 s and 45 s for non-splitting and splitting carbon-ion beams and 15 s and 66 s for non-splitting and splitting proton beams. Conclusions: The beam-splitting method was developed and verified to resolve the intrinsic size limitation of the Gaussian pencil-beam model in dose calculation algorithms. The computational speed slowed down by factor of 5, which would be tolerable for dose accuracy improvement at a maximum of 10%, in our test case. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | AAPM Annual Meeting 2009 | |||||
発表年月日 | ||||||
日付 | 2009-07-30 | |||||
日付タイプ | Issued |