ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Dynamic splitting of Gaussian pencil beams in heterogeneity-correction algorithms for radiotherapy with heavy charged particles

https://repo.qst.go.jp/records/69819
https://repo.qst.go.jp/records/69819
d4248a3c-fb73-43e0-8b11-a44ffa6ac558
Item type 会議発表用資料 / Presentation(1)
公開日 2009-08-02
タイトル
タイトル Dynamic splitting of Gaussian pencil beams in heterogeneity-correction algorithms for radiotherapy with heavy charged particles
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kanematsu, Nobuyuki

× Kanematsu, Nobuyuki

WEKO 685523

Kanematsu, Nobuyuki

Search repository
Komori, Masataka

× Komori, Masataka

WEKO 685524

Komori, Masataka

Search repository
Yonai, Shunsuke

× Yonai, Shunsuke

WEKO 685525

Yonai, Shunsuke

Search repository
Ishizaki, Azusa

× Ishizaki, Azusa

WEKO 685526

Ishizaki, Azusa

Search repository
兼松 伸幸

× 兼松 伸幸

WEKO 685527

en 兼松 伸幸

Search repository
小森 雅孝

× 小森 雅孝

WEKO 685528

en 小森 雅孝

Search repository
米内 俊祐

× 米内 俊祐

WEKO 685529

en 米内 俊祐

Search repository
石崎 梓

× 石崎 梓

WEKO 685530

en 石崎 梓

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose: To develop an algorithm to resolve intrinsic problems with dose calculations using pencil beams when particles involved in each beam are overreaching a lateral density interface or when they are detouring in a laterally heterogeneous medium. Method and Materials: A finding on a Gaussian distribution, such that it can be approximately decomposed into multiple narrower, shifted, and scaled ones, was applied to dynamic splitting of pencil beams implemented in a dose calculation algorithm for proton and ion beams. The method was tested in an experiment with a range-compensated carbon-ion beam. Its effectiveness and efficiency were evaluated for carbon-ion and proton beams in a heterogeneous phantom model. Results: The splitting dose calculation reproduced the detour effect observed in the experiment, which amounted to about 10% at a maximum or as large as the lateral particle-disequilibrium effect. The proton-beam dose generally showed large scattering effects including the overreach and detour effects. The overall computational times were 9 s and 45 s for non-splitting and splitting carbon-ion beams and 15 s and 66 s for non-splitting and splitting proton beams. Conclusions: The beam-splitting method was developed and verified to resolve the intrinsic size limitation of the Gaussian pencil-beam model in dose calculation algorithms. The computational speed slowed down by factor of 5, which would be tolerable for dose accuracy improvement at a maximum of 10%, in our test case.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 AAPM Annual Meeting 2009
発表年月日
日付 2009-07-30
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:10:03.965474
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3