A Multiplex OpenPET Geometry to Extend Axial FOV Without Increasing the Number of Detectors

https://repo.qst.go.jp/records/69555
https://repo.qst.go.jp/records/69555
b37c35e7-0210-433b-b84d-bcd4131a904d
Item type 会議発表用資料 / Presentation(1)
公開日 2008-10-30
タイトル
タイトル A Multiplex OpenPET Geometry to Extend Axial FOV Without Increasing the Number of Detectors
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Yamaya, Taiga

× Yamaya, Taiga

WEKO 682705

Yamaya, Taiga

Search repository
Yoshida, Eiji

× Yoshida, Eiji

WEKO 682706

Yoshida, Eiji

Search repository
Inadama, Naoko

× Inadama, Naoko

WEKO 682707

Inadama, Naoko

Search repository
Nishikido, Fumihiko

× Nishikido, Fumihiko

WEKO 682708

Nishikido, Fumihiko

Search repository
Shibuya, Kengo

× Shibuya, Kengo

WEKO 682709

Shibuya, Kengo

Search repository
Murayama, Hideo

× Murayama, Hideo

WEKO 682710

Murayama, Hideo

Search repository
山谷 泰賀

× 山谷 泰賀

WEKO 682711

en 山谷 泰賀

Search repository
吉田 英治

× 吉田 英治

WEKO 682712

en 吉田 英治

Search repository
稲玉 直子

× 稲玉 直子

WEKO 682713

en 稲玉 直子

Search repository
錦戸 文彦

× 錦戸 文彦

WEKO 682714

en 錦戸 文彦

Search repository
澁谷 憲悟

× 澁谷 憲悟

WEKO 682715

en 澁谷 憲悟

Search repository
村山 秀雄

× 村山 秀雄

WEKO 682716

en 村山 秀雄

Search repository
抄録
内容記述タイプ Abstract
内容記述 At the last MIC conference, we proposed an OpenPET geometry, which consists of two axially separated detector rings of axial length W. A long and continuous field-of-view (FOV) including a 360-degree open gap G between two detector rings can be imaged though iterative image reconstruction. In addition to providing stress-less PET scanning and simultaneous PET/CT, the OpenPET is expected to lead to realization of in-beam PET. The OpenPET also extends the axial FOV with a limited number of detectors. The range of G to obtain the axially continuous FOV is represented as aW (0<a<=1). The extension gain, which is defined as [extended axial FOV size] / [original axial FOV size], is limited to (2+a)/2. In order to increase the gap and the axial FOV, therefore, we have to extend W itself. However the extension of W results in cost enhancement of the scanner. In this paper, we propose a new multiplex OpenPET geometry, which can extend axial FOV without increasing the number of detectors. In the first step, two detector rings of axial length W are separated by the gap aW, and we have a pseudo scanner, unit[1], of axial length W[1] =(2+a)W. In the second step, two unit[1]s can be separated by the gap aW[1], and we have unit[2] of axial FOV W[2]=(2+a)2W. After repeating these steps N times, we finally have unit[N], which has a long axial FOV of W[N]=(2+a)NW. Here the extension gain is represented as {(2+a)/2}N. Theoretically it can be increased to an unlimited extent, although there is no gain in sensitivity. Simulation results show that fine reconstructed images are obtained by the multiplex OpenPET geometry. In addition to the extended gap, the proposed geometry is expected to help realize an affordable entire body PET scanner that enables whole body dynamic imaging.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 2008 Nuclear Science Symposium, Medical Imaging Conference
発表年月日
日付 2008-10-25
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:13:07.848435
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3