Simulation Study on Sensitivity and Count Rate Characteristics of OpenPET Geometries

https://repo.qst.go.jp/records/69553
https://repo.qst.go.jp/records/69553
b6d5d91f-66e7-453c-a579-242b6eec63c8
Item type 会議発表用資料 / Presentation(1)
公開日 2008-10-30
タイトル
タイトル Simulation Study on Sensitivity and Count Rate Characteristics of OpenPET Geometries
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Yoshida, Eiji

× Yoshida, Eiji

WEKO 682678

Yoshida, Eiji

Search repository
Yamaya, Taiga

× Yamaya, Taiga

WEKO 682679

Yamaya, Taiga

Search repository
Shibuya, Kengo

× Shibuya, Kengo

WEKO 682680

Shibuya, Kengo

Search repository
Nishikido, Fumihiko

× Nishikido, Fumihiko

WEKO 682681

Nishikido, Fumihiko

Search repository
Inadama, Naoko

× Inadama, Naoko

WEKO 682682

Inadama, Naoko

Search repository
Murayama, Hideo

× Murayama, Hideo

WEKO 682683

Murayama, Hideo

Search repository
吉田 英治

× 吉田 英治

WEKO 682684

en 吉田 英治

Search repository
山谷 泰賀

× 山谷 泰賀

WEKO 682685

en 山谷 泰賀

Search repository
澁谷 憲悟

× 澁谷 憲悟

WEKO 682686

en 澁谷 憲悟

Search repository
錦戸 文彦

× 錦戸 文彦

WEKO 682687

en 錦戸 文彦

Search repository
稲玉 直子

× 稲玉 直子

WEKO 682688

en 稲玉 直子

Search repository
村山 秀雄

× 村山 秀雄

WEKO 682689

en 村山 秀雄

Search repository
抄録
内容記述タイプ Abstract
内容記述 The "OpenPET" geometry, which consists of two axially separated detector rings, has been proposed to image the 360-degree open gap. The open gap is less stressful for patients and suitable for simultaneous PET/CT, entire whole-body PET and in-beam PET. It has been shown that OpenPET geometry can maintain high spatial resolution using a depth-of-interaction (DOI) detector. However, when the PET scanner is used for an extended axial field-of-view (FOV), several characteristics of oblique lines-of-response (LOR), such as decreased sensitivity due to smaller acceptance angle and increased scatter fraction (SF) and attenuation, should be carefully discussed. It is expected that these characteristics are dependent on the gap size and the target object size. In this work, we study sensitivity and count rate characteristics for OpenPET geometry using GATE simulation. We simulate three OpenPET geometries. (The dual scanner has 15-cm open gap and 45-cm axial FOV. The quad scanners have 30-cm open gap and 90-cm axial FOV.) When the gap is extended, the axial FOV is extended at the cost of the decreased sensitivity of the skirts of the main peak. Maximum sensitivity of the dual scanner with the open gap is almost the same as the scanner without the open gap. In the quad scanner, however, maximum sensitivity decreases by 25 % due to the decreased acceptance angles. Noise equivalent count rate (NECR) curves depend on not only the maximum sensitivity but also the target object size, because the extended gap results in the broadened sensitivity profile. For the 100-cm cylinder phantom with 100-cm line source, the loss of the peak NECR is slight for both scanners. For the 100-cm cylinder phantom with local activity, however, NECR of the quad scanner maintain approximately half of NECR without the open gap.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 2008 Nuclear Science Symposium, Medical Imaging Conference
発表年月日
日付 2008-10-25
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:13:09.361560
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3