Design and verification of measurement system for ion dose normalization in microbeam scanning PIXE system at NIRS
https://repo.qst.go.jp/records/69417
https://repo.qst.go.jp/records/69417314f6d75-9a08-4721-aff7-29d1a4f65a4b
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2008-07-29 | |||||
タイトル | ||||||
タイトル | Design and verification of measurement system for ion dose normalization in microbeam scanning PIXE system at NIRS | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Ishikawa, Takahiro
× Ishikawa, Takahiro× Iso, Hiroyuki× Oikawa, Masakazu× Konishi, Teruaki× Kitamura, Hisashi× Higuchi, Yuichi× Suya, Noriyoshi× Hamano, Tsuyoshi× Imaseki, Hitoshi× 石川 剛弘× 磯 浩之× 及川 将一× 小西 輝昭× 北村 尚× 樋口 有一× 酢屋 徳啓× 濱野 毅× 今関 等 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Microbeam scanning PIXE (micro-PIXE) analysis is a significant tool for obtaining information of multi-elemental distribution in the samples, as a two-dimensional image on the surface of the samples, such as mammalian cells, tissues, and other environmental monitoring species, Recently, in addition to elemental distribution information, quantitative analysis for the elements are desired. To make quantitative measurement possible, real-time beam monitoring system that gives precise measurement of exposure dose, and outputs independent from the targeted sample, and enables to keep the beam resolution of micrometer size. In this paper, we report about the design and development of ion dose normalization system for beam current monitoring. The beam current was monitored by detecting secondary electrons induced from a 10 g/cm2 thick carbon foil by ceramic channel electron multiplier (CEM). This carbon foil was attached to a sample holder, which was set on the sample targeted position. The output value of the CEM was proportional to the Faraday cup installed just after the sample position. Beam resolutions was measured using off-axis STIM by scanning at copper grid and were estimated at 1.79 and 1.72 m for the horizontal and vertical directions, respectively, sufficient for routine micro-PIXE) analysis. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 11th International Conference on Nuclear Microprobe Technology and Applications 2008 | |||||
発表年月日 | ||||||
日付 | 2008-07-25 | |||||
日付タイプ | Issued |