WEKO3
アイテム
Update of an accelerator control system for the new treatment facility at HIMAC.
https://repo.qst.go.jp/records/69394
https://repo.qst.go.jp/records/69394e2e023c3-f6f4-4483-a948-79df7de2de59
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2008-07-02 | |||||
タイトル | ||||||
タイトル | Update of an accelerator control system for the new treatment facility at HIMAC. | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Iwata, Yoshiyuki
× Iwata, Yoshiyuki× 岩田 佳之 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The control scheme of the HIMAC accelerators has been developed for the new treatment facility, which will be constructed adjacent to the existing HIMAC accelerator complex. The new treatment facility will have three treatment rooms, where a raster-scanning irradiation will be performed. To fulfill requirements of the scanning irradiation, we are developing a control scheme for a multiple-level-flattop operation. With this control, the beam energy can be continuously varied within a single synchrotron cycle. Successful results of beam acceleration and extraction tests proved the feasibility of the multiple-energy operation. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | European Particle Accelerator Conference 2008 (EPAC08) | |||||
発表年月日 | ||||||
日付 | 2008-06-27 | |||||
日付タイプ | Issued |