ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Measurement of Mn, Ni, Cu, Zn, As, Se, Mo and Pb in urine samples by octapole reaction system ICP-MS

https://repo.qst.go.jp/records/69214
https://repo.qst.go.jp/records/69214
6bc6d1e7-63c7-4ce5-b459-f405b9d670f0
Item type 会議発表用資料 / Presentation(1)
公開日 2007-12-04
タイトル
タイトル Measurement of Mn, Ni, Cu, Zn, As, Se, Mo and Pb in urine samples by octapole reaction system ICP-MS
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Tagami, Keiko

× Tagami, Keiko

WEKO 679172

Tagami, Keiko

Search repository
Uchida, Shigeo

× Uchida, Shigeo

WEKO 679173

Uchida, Shigeo

Search repository
et.al

× et.al

WEKO 679174

et.al

Search repository
田上 恵子

× 田上 恵子

WEKO 679175

en 田上 恵子

Search repository
内田 滋夫

× 内田 滋夫

WEKO 679176

en 内田 滋夫

Search repository
抄録
内容記述タイプ Abstract
内容記述 Consumption of contaminated drinking water and foods with metals is of great concern from the viewpoint of public health. It is already known that a large-scale poisoning by arsenic (As) has become one of the major issues in developing countries mainly due to its high concentration in bedrocks. To evaluate metal concentration effects on human health, it is necessary to measure elemental concentrations in biological samples, such as urine. In this study, we used an octapole reaction system ICP-MS (ORS-ICP-MS) to measure Mn, Ni, Cu, Zn, As, Se, Mo and Pb in urine samples. We also measured river water samples for comparison. The ORS can be used to eliminate isobaric interferences by introducing H2 or He gas into the octapole reaction cell.
Reference urine sample (NIES, No.18) were used to check applicability of ORS-ICP-MS for determination of these elements. The sample was diluted in 3.5% HNO3 solution and was directly measured by ORS-ICP-MS using the H2 gas mode for Mn, Zn, Se and Pb, and the He gas mode for Ni, Cu, As and Mo. The results demonstrated that the analytical results agreed well with the certified values within the error. Using this simple method, we measured concentrations of urine samples collected in Bangladesh.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 International Symposium on Metallomics 2007
発表年月日
日付 2007-12-01
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:17:08.342545
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3