ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Biological Experiments Related Radiation-Induced Responses with Synchrotron X-Ray Microbeam at the Photon Factory

https://repo.qst.go.jp/records/69171
https://repo.qst.go.jp/records/69171
885f2ccc-bb92-4935-bc4d-b9a53b44e766
Item type 会議発表用資料 / Presentation(1)
公開日 2007-11-19
タイトル
タイトル Biological Experiments Related Radiation-Induced Responses with Synchrotron X-Ray Microbeam at the Photon Factory
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Usami, Noriko

× Usami, Noriko

WEKO 678767

Usami, Noriko

Search repository
Eguchi-Kasai, Kiyomi

× Eguchi-Kasai, Kiyomi

WEKO 678768

Eguchi-Kasai, Kiyomi

Search repository
Mori, Masahiko

× Mori, Masahiko

WEKO 678769

Mori, Masahiko

Search repository
Maezawa, Hiroshi

× Maezawa, Hiroshi

WEKO 678770

Maezawa, Hiroshi

Search repository
Kobayashi, Katsumi

× Kobayashi, Katsumi

WEKO 678771

Kobayashi, Katsumi

Search repository
宇佐美 徳子

× 宇佐美 徳子

WEKO 678772

en 宇佐美 徳子

Search repository
笠井 清美

× 笠井 清美

WEKO 678773

en 笠井 清美

Search repository
森 雅彦

× 森 雅彦

WEKO 678774

en 森 雅彦

Search repository
前澤 博

× 前澤 博

WEKO 678775

en 前澤 博

Search repository
小林 克己

× 小林 克己

WEKO 678776

en 小林 克己

Search repository
抄録
内容記述タイプ Abstract
内容記述 An X-ray microbeam irradiation system using synchrotron radiation has been developed at the Photon Factory, KEK, Japan, and now fully operated for various biological experiments. The energy of microbeam X-rays is 5.35 keV which is suitable for experiments using mammalian cells, because the X-rays can penetrate the thickness of cells and the range of secondary electrons are within few micrometers. Detail of the system and future developments are presented elsewhere in these abstracts.
The synchrotron radiation has extremely low divergence, so it is easy to get X-ray beam with micrometer-dimension. Thus, the high-precision slit installed in the system can provide a simplest way to get microbeam without focusing. The minimum beamsize by the slit is 5-um square, and the size of the microbeam can be changed quickly. This spec might be ideal to investigate the damage localization in the cell or cell nuclei irradiated with subcellular-sized beam. We tried to visualize the DNA damage produced in the microbeam-irradiated human cells with an immunostaining of phosphorylated histone H2AX (gamma-H2AX). Human fibroblast cells (NB1RGB) were grown in alfa-MEM containing 10% FBS and inoculated to the specially-designed dishes, the bottom of which was made of a thin polymer film (Mylar or polypropylene). The cells were incubated for 12 hours to attach the surface of the polymer. Before irradiation, the cell nuclei were stained with the medium containing 1uM Hoechst 33258 for 30 min. The dish was set on the microbeam system and the positions of cell nuclei were recorded with the specially-developed software and then irradiated with X-ray microbeam. The cells were irradiated with two different beam-size of microbeam, either 5- or 10-um square. The fluence of microbeam were 1.4 x 10^4 photons/(10 um)^2 per sec, which is equivalent to the X-rays of 0.4 Gy per sec. After irradiation, cells were incubated at 37 degree in C for 15 min and fixed in 100% methanol for 20 min and 100% acetone for 10 sec at 0 degree in C. Then cells were blocked with 1% FBS for 10 min, incubated with the gamma-H2AX antibody (provided by Sawady Technology), washed, and incubated with FITC-conjugated donkey anti-rabbit IgG (Santa Cruz Biotechnology, Inc). The nuclei of the cells were also stained with 1 ug/ml of propidium iodide after the immunostaining process. The dish was set on the microbeam system again, and the system automatically revisited the position of the targeted cells. The targeted cells were viewed with the epi-fluorescent microscope installed in the system. We also observed the cells by a confocal laser scanning microscope installed recently as an "off-line detection system". All the irradiated cells could be found at the revisited position, and could be distinguished from surrounding unirradiated cells by their high yield of fluorescence of gamma-H2AX. Most fluorescent foci were observed in localized area in cell nuclei, the sizes of which were almost the same as the beam size. Difference in size of the stained area can be easily recognized between cells irradiated 5-um beam and those irradiated with 10-um beam. This result also demonstrates that the system has enough accuracy and repeatability to target a part of the individual cell nuclei. Dose dependence of gamma-H2AX induction was also clearly observed, within the dose range equivalent to 2 - 6 Gy X-rays. Recently, we have started the investigation to visualize the accumulation of DNA-repair-related proteins by using Chinese hamster cells with GFP-Rad51. Within 2 hours after irradiation, there are significant number of foci of GFP-Rad51 were clearly observed in the nuclei of the microbeam-irradiated cells. Experiments for the time-course of the protein accumulation is now in progress.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 7th International Workshop Microbeam probes of cellular radiation response
発表年月日
日付 2006-03-17
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:17:40.074516
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3