ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Development of treatment planning for scanning irradiation at HIMAC

https://repo.qst.go.jp/records/69104
https://repo.qst.go.jp/records/69104
81b0df52-e375-490b-800e-bdf53c9ae7f0
Item type 会議発表用資料 / Presentation(1)
公開日 2007-09-27
タイトル
タイトル Development of treatment planning for scanning irradiation at HIMAC
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Inaniwa, Taku

× Inaniwa, Taku

WEKO 678093

Inaniwa, Taku

Search repository
稲庭 拓

× 稲庭 拓

WEKO 678094

en 稲庭 拓

Search repository
抄録
内容記述タイプ Abstract
内容記述 A project to construct a new treatment facility as an extension of the existing Heavy-Ion Medical Accelerator in Chiba (HIMAC) facility has been initiated for further development of carbon-ion therapy at National Institute of Radiological Sciences (NIRS). In the facility, the raster scanning irradiation method will be utilized instead of the conventional passive irradiation method. In order to achieve the planned 3D dose distribution with the method, the best particle numbers (weight) and positions of each pencil beam, i.e. the best 3D matrix of the pencil beams, must be found at the stage of treatment planning. In order to assess the quality of the irradiation method through beam experiments, we started to develop the research version of the treatment planning tool along with the design study of the irradiation system. When the planned target volume (PTV) delineated on patient’s CT was imported to the planning tool, the best beam steering file can be derived. The scanning sequence of each raster point is determined by applying the traveling salesman problem (TSP). Furthermore, the extra dose in raster scanning, indicating the dose delivered during the transition time from one spot to the next spot in raster scanning, is incorporated to the inverse planning calculation in order to shorten the beam irradiation time as much as possible. The irradiation experiment was performed at the secondary beam course in HIMAC using derived beam steering file, and the reliability of the planning tool is confirmed. In the meeting, the details of the development of the planning tool and the experimental results will be shown.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 ECAART9
発表年月日
日付 2007-09-07
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:18:27.429118
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3