ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Improvement of PET image quality using DOI and TOF information.

https://repo.qst.go.jp/records/69056
https://repo.qst.go.jp/records/69056
9bfc93e1-90cb-428b-b33b-1127a202edee
Item type 会議発表用資料 / Presentation(1)
公開日 2007-07-23
タイトル
タイトル Improvement of PET image quality using DOI and TOF information.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kobayashi, Tetsuya

× Kobayashi, Tetsuya

WEKO 677757

Kobayashi, Tetsuya

Search repository
小林 哲哉

× 小林 哲哉

WEKO 677758

en 小林 哲哉

Search repository
抄録
内容記述タイプ Abstract
内容記述 This paper investigates the benefit of depth-of-interaction (DOI) information in a time-of-flight (TOF) positron emission tomography (PET). TOF measurement, generally, has advantages to large bore scanners, and it improves signal-to-noise ratio of reconstructed images. On the other hand, DOI measurement has advantages to small bore scanners such as dedicated brain PET scanners or small animal PET scanners. DOI measurement provides uniform spatial resolution in the field-of-view (FOV) by minimizing resolution loss due to a parallax error. Therefore PET imaging using both TOF and DOI information has not investigated to date. We simulated two dimensional whole-body PET scanners with one-layer (i.e. non-DOI) and four-layer DOI capability using the GATE (Geant4 Application for Emission Tomography). The length of a short side of the crystal element was 2.9mm, and total thickness of the detector block of both scanners was 20mm. These scanners were assumed to have 200ps, 400ps and 800ps timing resolution. We developed a histogram based ordered-subsets expectation-maximization with accurate modeling of detector response and TOF kernel. Two simulations were performed to evaluate spatial resolution and contrast recovery. The results show that the spatial resolution, contrast recovery and their uniformity in the FOV degrades greatly with a parallax error of the non-DOI scanner; however the DOI scanner provides uniform resolution of approximately 2mm full width at half maximum in the whole FOV of 60cm diameter. Reconstruction with improved timing resolution provides higher contrast recovery at the low background noise level.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 Fully Three-Dimensional Image Reconstruction Meeting in Radiology and Nuclear Medicine
発表年月日
日付 2007-07-13
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:19:00.444640
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3