ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

An improvement of the metaphase finder system for the biological dosimetry by chromosome aberration

https://repo.qst.go.jp/records/69054
https://repo.qst.go.jp/records/69054
4b44b492-fa9b-47f1-ad2c-ab430f161993
Item type 会議発表用資料 / Presentation(1)
公開日 2007-07-23
タイトル
タイトル An improvement of the metaphase finder system for the biological dosimetry by chromosome aberration
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Furukawa, Akira

× Furukawa, Akira

WEKO 677752

Furukawa, Akira

Search repository
et.al

× et.al

WEKO 677753

et.al

Search repository
古川 章

× 古川 章

WEKO 677754

en 古川 章

Search repository
抄録
内容記述タイプ Abstract
内容記述 For biological dosimetry by counting chromosomes aberrations, automation technique has been required to process large number of sample preparations at low dose radiation exposure, or at large number of people who wants the exposure test.
The metaphase finder is an automated optical microscope system, which automatically scans and finds metaphase cells on the slide glass, and relocates metaphase cells to the center of the field of view of the microscope to observe chromosomes in high magnification.
We have constructed a Metaphase Finder system by assembling commercially available components, such as microscope, motorized sample stage, personal computer and general purpose image analysis software package, instead of purchasing one dedicated system.
The new points of recent system were camera's view field became larger than before, and morphology-based improved image processing method was used. Our system has begun to practically use in several domestic laboratories.
The purpose of this paper is to test the performance of this new Metaphase Finder system. The results were: The scanning speed was 22 min/cm2. The false positive rate was 2 %.
The speed was slower than several commercial metaphase finders but enough for practical use.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 The 13TH International Congress of RadiationResearch
発表年月日
日付 2007-07-12
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:19:01.757733
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3