ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Estimation of RBE Values for Carbon-Ion Beams at High-Dose Region Using Multicellular Spheroids of HMV-I Cells

https://repo.qst.go.jp/records/69038
https://repo.qst.go.jp/records/69038
3cad00ce-ea11-4aad-85a8-5b022ce09b02
Item type 会議発表用資料 / Presentation(1)
公開日 2007-07-18
タイトル
タイトル Estimation of RBE Values for Carbon-Ion Beams at High-Dose Region Using Multicellular Spheroids of HMV-I Cells
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Matsumoto, Yoshitaka

× Matsumoto, Yoshitaka

WEKO 677562

Matsumoto, Yoshitaka

Search repository
Shimao, Daisuke

× Shimao, Daisuke

WEKO 677563

Shimao, Daisuke

Search repository
Aoki, Mizuho

× Aoki, Mizuho

WEKO 677564

Aoki, Mizuho

Search repository
Hirayama, Ryoichi

× Hirayama, Ryoichi

WEKO 677565

Hirayama, Ryoichi

Search repository
Kubota, Nobuo

× Kubota, Nobuo

WEKO 677566

Kubota, Nobuo

Search repository
Ando, Koichi

× Ando, Koichi

WEKO 677567

Ando, Koichi

Search repository
Tsujii, Hirohiko

× Tsujii, Hirohiko

WEKO 677568

Tsujii, Hirohiko

Search repository
Furusawa, Yoshiya

× Furusawa, Yoshiya

WEKO 677569

Furusawa, Yoshiya

Search repository
松本 孔貴

× 松本 孔貴

WEKO 677570

en 松本 孔貴

Search repository
青木 瑞穂

× 青木 瑞穂

WEKO 677571

en 青木 瑞穂

Search repository
平山 亮一

× 平山 亮一

WEKO 677572

en 平山 亮一

Search repository
窪田 宜夫

× 窪田 宜夫

WEKO 677573

en 窪田 宜夫

Search repository
安藤 興一

× 安藤 興一

WEKO 677574

en 安藤 興一

Search repository
辻井 博彦

× 辻井 博彦

WEKO 677575

en 辻井 博彦

Search repository
古澤 佳也

× 古澤 佳也

WEKO 677576

en 古澤 佳也

Search repository
抄録
内容記述タイプ Abstract
内容記述 (Introduction) Heavy-ion beams have good dose distribution for tumor. Carbon beams, accelerated by HIMAC in National Institute of Radiological Sciences (NIRS), is a candidate for use in hypofractionated radiotherapy of tumors included malignant melanoma of choroid, non-small cell lung cancer or hepatocellular carcinoma. In this case, relative biological effectiveness (RBE) at high dose region (low survival level) must be considered however, the RBE is calculated physically and not verified biologically. (Purpose) The purpose of this study is to estimate RBE at high dose range as well as low dose range using monolayer cells and multicellular spheroids. (Materials and Methods) One human malignant melanoma cell line, HMV-I was used for this study. We used the 96 wells spheroid plates (SUMILOM MS-0096S) for making the multicellular spheroids. Cells were irradiated with 290 MeV/u carbon ions, 490 MeV/u silicon ions or 500 MeV/u argon ions with a dose-averaged about 13, 35, 100 and 300keV/um LET and X-rays. (Results) Surviving fractions of cells exposed to carbon beams and X-rays at a lower dose range (0-8 Gy) and a higher range (8-15 Gy) were obtained using monolayer cells and multicellular spherooids, respectively. The lenear-quadratic (LQ) equation fits well in survival data of monolayer cultures after both radiation at lower dose region. The multi-target single-hit (MT) equation fits well in those of spheroids at higher dose region. In addition, we could fit with a formula combined MT equation and initial slope part of LQ equation as well as multi-process (MP) equation, to survival data. This equation has good fitting for survival data in wide dose range when both monolayer and spheroid data was combined. (Conclusion) We could estimate RBE values of carbon beams from low to high dose range by converting the surviving fractions of spheroids into monolayer cells using the MP equation. RBE values at high dose range converged on the fixed values at 1.1-1.4, but varied in LET values at very low dose range (0-4 Gy).
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 The 13th International Congress of Radiation Research
発表年月日
日付 2007-07-12
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:19:13.526244
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3