ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Isotope dilution SF-ICP-MS for precise determination of Pu isotopes in a seawater reference material

https://repo.qst.go.jp/records/68881
https://repo.qst.go.jp/records/68881
be8f78a7-f4eb-44bc-8169-8c4636d21442
Item type 会議発表用資料 / Presentation(1)
公開日 2007-03-26
タイトル
タイトル Isotope dilution SF-ICP-MS for precise determination of Pu isotopes in a seawater reference material
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Zheng, Jian

× Zheng, Jian

WEKO 675986

Zheng, Jian

Search repository
Yamada, Masatoshi

× Yamada, Masatoshi

WEKO 675987

Yamada, Masatoshi

Search repository
鄭 建

× 鄭 建

WEKO 675988

en 鄭 建

Search repository
山田 正俊

× 山田 正俊

WEKO 675989

en 山田 正俊

Search repository
抄録
内容記述タイプ Abstract
内容記述 In order to obtain precise Pu isotope composition of Irish Sea water reference material issued by the International Atomic Energy Agency (IAEA-381), we analyzed the activities of 239Pu, 240Pu, 239+240Pu and the atom ratio of 240Pu/239Pu by a highly sensitive isotope dilution SF-ICP-MS method combined with two-stage chromatographic separation and purification. With a mean chemical yield of 65 % for 242Pu tracer, the experimentally established values for 239Pu, 240Pu and 239+240Pu activities are in good agreement with the certified ones. For the 240Pu/239Pu atom ratio, we obtain a value of 0.2315  0.0008 with a high precision (RSD, 0.35 %), which is much more precise and reliable than the information value of 0.22  0.03 (RSD, 13.6 %) provided by the IAEA certification report.
Due to the low concentration of Pu isotopes in the marine environment, the determination of 240Pu/239Pu atom ratio, which is extremely important and useful for the source identification, by ICP-MS has to be done at ultra-trace level (tens and/or hundreds of fg Pu). The validation of the analytical method, including the correction of possible mass discrimination effect during the ICP-MS measurement, is essential to obtain reliable results. As the Pu isotope standard with certified Pu isotope ratio is no longer commercially available, the use of certified U isotope standard has commonly been used as an alternative approach for the mass bias correction, however, this correction is complicated. It is expected that our results on the precise determination of 240Pu/239Pu atom ratio can spark additional similar work, so that a consensus value of the 240Pu/239Pu atom ratio with high precision can be reached for the IAEA-381 seawater reference material, thus making it an ideal reference material for not only method validation for seawater samples, but also for more general use as a Pu isotope standard for the mass discrimination correction for other environmental samples when using ICP-MS techniques.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 第8回環境放射能研究会
発表年月日
日付 2007-03-24
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:21:01.868604
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3