WEKO3
アイテム
MR Diffusion-weighted imaging(DWI) of Malignant Melanoma in Head and Neck after Accelerated Carbon-Ion Radiotherapy
https://repo.qst.go.jp/records/68872
https://repo.qst.go.jp/records/688721f53e659-d3a4-4c8b-a10f-c478d072c4f0
| Item type | 会議発表用資料 / Presentation(1) | |||||
|---|---|---|---|---|---|---|
| 公開日 | 2007-03-19 | |||||
| タイトル | ||||||
| タイトル | MR Diffusion-weighted imaging(DWI) of Malignant Melanoma in Head and Neck after Accelerated Carbon-Ion Radiotherapy | |||||
| 言語 | ||||||
| 言語 | eng | |||||
| 資源タイプ | ||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
| 資源タイプ | conference object | |||||
| アクセス権 | ||||||
| アクセス権 | metadata only access | |||||
| アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
| 著者 |
Tanabe, Kouji
× Tanabe, Kouji× Kandatsu, Susumu× Kishimoto, Riwa× Mizoe, Junetsu× 田辺 耕士× 神立 進× 岸本 理和× 溝江 純悦 |
|||||
| 抄録 | ||||||
| 内容記述タイプ | Abstract | |||||
| 内容記述 | PURPOSE: To report change of diffusion weighted imaging(DWI) of malignant melanoma in head and neck after carbon-ion radiotherapy. MATERIAL and METHOD: Eighteen patients having malignant melanoma in head and neck regions undertook carbon-ion radiotherapy at the National Institute of Radiological Sciences, Chiba, Japan. We examined using DWIBS (diffusion-weighted imaging with background body signal suppression) method before and after the treatment. ADC (apparent diffusion coefficient) value was measurable in nine of 18 cases (mean age:65yrs,age range:56-78,5 males and 4 females). We compared the ADC value before the treatment with the after one. Intera Achieva 1.5T Nova Dual system (Philips Medical) was used for the examination. The EPI-based diffusion-weighted imaging sequence with SPIR fat suppression was applied at the settings of two b-values, namely 0 and 1000 sec/mm^2, respectively. Results: Average ADC value for all clinical cases were 0.897x10^-3 (S.D.: 0.142x10^-3) at pre-treatment and 1.355x10^-3 (S.D.: 0.573x10^-3) at post-treatment. ADC values were increased in eight of 9 cases and decreased in one. There was a significant difference in ADC value between pre- and post-treatment (P<0.028). CONCLUSIONS: DWIBS examination for malignant melanoma in head and neck showed significant increases in ADC value after carbon-ion radiotherapy. The ADC value has the possibility of becoming a criteria when you judge the effect of the carbon-ion radiotherapy in malignant melanoma. |
|||||
| 会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
| 内容記述タイプ | Other | |||||
| 内容記述 | ECR2007 19th European Congress of Radiology | |||||
| 発表年月日 | ||||||
| 日付 | 2007-03-13 | |||||
| 日付タイプ | Issued | |||||