MR Diffusion-weighted imaging(DWI) of Malignant Melanoma in Head and Neck after Accelerated Carbon-Ion Radiotherapy

https://repo.qst.go.jp/records/68872
https://repo.qst.go.jp/records/68872
1f53e659-d3a4-4c8b-a10f-c478d072c4f0
Item type 会議発表用資料 / Presentation(1)
公開日 2007-03-19
タイトル
タイトル MR Diffusion-weighted imaging(DWI) of Malignant Melanoma in Head and Neck after Accelerated Carbon-Ion Radiotherapy
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Tanabe, Kouji

× Tanabe, Kouji

WEKO 675924

Tanabe, Kouji

Search repository
Kandatsu, Susumu

× Kandatsu, Susumu

WEKO 675925

Kandatsu, Susumu

Search repository
Kishimoto, Riwa

× Kishimoto, Riwa

WEKO 675926

Kishimoto, Riwa

Search repository
Mizoe, Junetsu

× Mizoe, Junetsu

WEKO 675927

Mizoe, Junetsu

Search repository
田辺 耕士

× 田辺 耕士

WEKO 675928

en 田辺 耕士

Search repository
神立 進

× 神立 進

WEKO 675929

en 神立 進

Search repository
岸本 理和

× 岸本 理和

WEKO 675930

en 岸本 理和

Search repository
溝江 純悦

× 溝江 純悦

WEKO 675931

en 溝江 純悦

Search repository
抄録
内容記述タイプ Abstract
内容記述 PURPOSE: To report change of diffusion weighted imaging(DWI) of malignant melanoma in head and neck after carbon-ion radiotherapy. MATERIAL and METHOD: Eighteen patients having malignant melanoma in head and neck regions undertook carbon-ion radiotherapy at the National Institute of Radiological Sciences, Chiba, Japan. We examined using DWIBS (diffusion-weighted imaging with background body signal suppression) method before and after the treatment. ADC (apparent diffusion coefficient) value was measurable in nine of 18 cases (mean age:65yrs,age range:56-78,5 males and 4 females). We compared the ADC value before the treatment with the after one. Intera Achieva 1.5T Nova Dual system (Philips Medical) was used for the examination. The EPI-based diffusion-weighted imaging sequence with SPIR fat suppression was applied at the settings of two b-values, namely 0 and 1000 sec/mm^2, respectively.
Results: Average ADC value for all clinical cases were 0.897x10^-3 (S.D.: 0.142x10^-3) at pre-treatment and 1.355x10^-3 (S.D.: 0.573x10^-3) at post-treatment. ADC values were increased in eight of 9 cases and decreased in one. There was a significant difference in ADC value between pre- and post-treatment (P<0.028).
CONCLUSIONS: DWIBS examination for malignant melanoma in head and neck showed significant increases in ADC value after carbon-ion radiotherapy. The ADC value has the possibility of becoming a criteria when you judge the effect of the carbon-ion radiotherapy in malignant melanoma.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 ECR2007 19th European Congress of Radiology
発表年月日
日付 2007-03-13
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:21:07.737723
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3