ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Evaluation of detectability and diagnostic capability for neck lymphnode metastasis from head and neck cancer using C-11 methionine PET/CT

https://repo.qst.go.jp/records/68841
https://repo.qst.go.jp/records/68841
b05a8c17-7b76-4b51-917f-de106e4c45bf
Item type 会議発表用資料 / Presentation(1)
公開日 2007-01-22
タイトル
タイトル Evaluation of detectability and diagnostic capability for neck lymphnode metastasis from head and neck cancer using C-11 methionine PET/CT
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Hasebe, Mitsuhiko

× Hasebe, Mitsuhiko

WEKO 675669

Hasebe, Mitsuhiko

Search repository
Yoshikawa, Kyosan

× Yoshikawa, Kyosan

WEKO 675670

Yoshikawa, Kyosan

Search repository
Ishikawa, Hiroyuki

× Ishikawa, Hiroyuki

WEKO 675671

Ishikawa, Hiroyuki

Search repository
Mizoe, Junetsu

× Mizoe, Junetsu

WEKO 675672

Mizoe, Junetsu

Search repository
Seto, Kanichi

× Seto, Kanichi

WEKO 675673

Seto, Kanichi

Search repository
Tsujii, Hirohiko

× Tsujii, Hirohiko

WEKO 675674

Tsujii, Hirohiko

Search repository
長谷部 充彦

× 長谷部 充彦

WEKO 675675

en 長谷部 充彦

Search repository
吉川 京燦

× 吉川 京燦

WEKO 675676

en 吉川 京燦

Search repository
石川 博之

× 石川 博之

WEKO 675677

en 石川 博之

Search repository
溝江 純悦

× 溝江 純悦

WEKO 675678

en 溝江 純悦

Search repository
辻井 博彦

× 辻井 博彦

WEKO 675679

en 辻井 博彦

Search repository
抄録
内容記述タイプ Abstract
内容記述 PURPOSE : We performed C-11 methionine PET/CT(MET-PET/CT) for patients with head and neck cancer and evaluated detectability and diagnostic capability for neck lymphnode metastasis.
METHOD AND MATERIALS : Ninety-three patients with proven head and neck cancer admitted in our hospital for carbon ion rediotherapy were studied with MET-PET/CT before treatment. We found out 32 patients with any nodular accumulation in neck region from these patients. There were 47 nodules,suspicious candidate for lymph node metastasis.There were 12 malignant melanoma, 6 squamous cell carcinoma, 4 adenocarcinoma, 4 adenoid cystic carcinoma and 6 other carcinomas. We evaluated diagnostic characetenistics such as diagnostic indexes and ROC curve analysis.We use semi-quantitative parameter TNR,tumor to normal tissue ratio,for nodule activity.We analyzed the relation ship between TNR and noduls size,the CT diagnosis result using size critenia for lymph node metastasis and the clinical diagnosis result from long term follow up,respectively.
RESULTS : Mean TNR of all nodules was 2.3(range:1.2-4.5)and mean nodule size was 8.6 mm(range:4.7-17.7mm).Correlation coefficient was 0.54, weekly correlated, between neck nodule activity and size. We classified nodules according to CT size into two groups. There were 9 nodules greater than 10 mm, the group diagnosed as metastasis, 38 nodules less than 10 mm in diameter. There was statistically significant dfference in nodule TNR between the two groups (p=0.001). Patients were followed for 6 to 36 months (mean: 14.3 months) and 20 nodules were diagnosed as metastasis. When we use CT size criteria or TNR (cutoff value 2.17), sensitivity, specificity and accuracy were 77.7%, 65.8% and 68.0% for CT size, 72.7%, 84.0% and 77.7% for TNR, respectively. Specificity and accuracy of the result using TNR value were superior to that of CT size criteria. From ROC curve analysis, Az value was 0.80.
CONCLUSION : MET-PET/CT can be used as a valuable tool for assessing lymph node metastasis in patients with head and neck cancer, and it can diagnose neck metastasis more accurately than CT size criteria.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 92nd Scientific Assembly and Annual Meeting
発表年月日
日付 2006-12-01
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:21:28.919078
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3