First human brain images of the jPET-D4 using 3D OS-EM with a pre-computed system matrix

https://repo.qst.go.jp/records/68767
https://repo.qst.go.jp/records/68767
7cd15cc4-4bf2-4f0d-9159-21df4b7af4aa
Item type 会議発表用資料 / Presentation(1)
公開日 2006-11-13
タイトル
タイトル First human brain images of the jPET-D4 using 3D OS-EM with a pre-computed system matrix
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Yamaya, Taiga

× Yamaya, Taiga

WEKO 674856

Yamaya, Taiga

Search repository
Yoshida, Eiji

× Yoshida, Eiji

WEKO 674857

Yoshida, Eiji

Search repository
Kitamura, Keishi

× Kitamura, Keishi

WEKO 674858

Kitamura, Keishi

Search repository
Obi, Takashi

× Obi, Takashi

WEKO 674859

Obi, Takashi

Search repository
Tanimoto, Katsuyuki

× Tanimoto, Katsuyuki

WEKO 674860

Tanimoto, Katsuyuki

Search repository
Yoshikawa, Kyosan

× Yoshikawa, Kyosan

WEKO 674861

Yoshikawa, Kyosan

Search repository
Ito, Hiroshi

× Ito, Hiroshi

WEKO 674862

Ito, Hiroshi

Search repository
Murayama, Hideo

× Murayama, Hideo

WEKO 674863

Murayama, Hideo

Search repository
山谷 泰賀

× 山谷 泰賀

WEKO 674864

en 山谷 泰賀

Search repository
吉田 英治

× 吉田 英治

WEKO 674865

en 吉田 英治

Search repository
北村 圭司

× 北村 圭司

WEKO 674866

en 北村 圭司

Search repository
小尾 高史

× 小尾 高史

WEKO 674867

en 小尾 高史

Search repository
谷本 克之

× 谷本 克之

WEKO 674868

en 谷本 克之

Search repository
吉川 京燦

× 吉川 京燦

WEKO 674869

en 吉川 京燦

Search repository
伊藤 浩

× 伊藤 浩

WEKO 674870

en 伊藤 浩

Search repository
村山 秀雄

× 村山 秀雄

WEKO 674871

en 村山 秀雄

Search repository
抄録
内容記述タイプ Abstract
内容記述 The jPET-D4 is a novel brain PET scanner which aims to achieve not only high spatial resolution but also high scanner sensitivity by measuring 4-layer depth-of-interaction (DOI) information. In this work, we present software strategies for 3D image reconstruction and imaging performance of the jPET-D4 prototype. The dimensions of a system matrix for the jPET-D4 become 4 billion (coincidence pairs) x 5 million (image elements) when a 25cm diameter FOV is sampled by a 1.5mm3 voxel. The size of the system matrix is estimated at 142peta (P) byte with the accuracy of 8 byte per element. The on-the-fly calculation is usually used to deal with a huge system matrix. However we can not avoid the extension of calculation time when we improve the accuracy of system modeling. In this work, we proposed an alternative approach based on the pre-calculation of the system matrix. The 142P byte system matrix was compressed into 13.4GB by (1) reducing zero elements, (2) applying the 3D-expanded DOI compression method, (3) factorizing with respect to ring differences and (4) restricting the maximum ring difference to 54 (with only 10% loss of the number of LORs). Histogram-based 3D OSEM based on geometrical system modeling was implemented on a single Itanium 1.6GHz PC with 16Gbyte memory. After evaluating basic imaging performance though phantom experiments, a normal volunteer was scanned (100 min past 104MBq FDG injection, duration 66 min) and the first human brain images were obtained.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 IEEE 2006 Nuclear Science Symposium and Medical Imaging Conference
発表年月日
日付 2006-11-04
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:22:21.700568
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3