ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Evaluation of Optimal Scan Time by Bootstrap Approach for Quantitative Analysis in PET Receptor Study

https://repo.qst.go.jp/records/68765
https://repo.qst.go.jp/records/68765
93e00737-b074-4e79-998d-6a5c89cfbf51
Item type 会議発表用資料 / Presentation(1)
公開日 2006-11-13
タイトル
タイトル Evaluation of Optimal Scan Time by Bootstrap Approach for Quantitative Analysis in PET Receptor Study
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Ikoma, Youko

× Ikoma, Youko

WEKO 674833

Ikoma, Youko

Search repository
Shidahara, Miho

× Shidahara, Miho

WEKO 674834

Shidahara, Miho

Search repository
Ito, Hiroshi

× Ito, Hiroshi

WEKO 674835

Ito, Hiroshi

Search repository
Seki, Chie

× Seki, Chie

WEKO 674836

Seki, Chie

Search repository
Suhara, Tetsuya

× Suhara, Tetsuya

WEKO 674837

Suhara, Tetsuya

Search repository
Kanno, Iwao

× Kanno, Iwao

WEKO 674838

Kanno, Iwao

Search repository
生駒 洋子

× 生駒 洋子

WEKO 674839

en 生駒 洋子

Search repository
志田原 美保

× 志田原 美保

WEKO 674840

en 志田原 美保

Search repository
伊藤 浩

× 伊藤 浩

WEKO 674841

en 伊藤 浩

Search repository
関 千江

× 関 千江

WEKO 674842

en 関 千江

Search repository
須原 哲也

× 須原 哲也

WEKO 674843

en 須原 哲也

Search repository
菅野 巖

× 菅野 巖

WEKO 674844

en 菅野 巖

Search repository
抄録
内容記述タイプ Abstract
内容記述 Quantification of the binding potential (BP) of the receptor in human brain has been performed with PET. In this quantitative analysis, the error of estimated kinetic parameter is affected by the noise depends on the sensitivity of PET camera, injection dose, scan protocol, and so on. The evaluation of reliability of estimated kinetic parameter is important for the optimization of scan protocol and quantitative analysis method. However, the estimation of reliability is not easy for human data because the true noise level is not precisely known. In this study, we have evaluated a method for estimating the reliability of estimated kinetic parameter with bootstrap approach in the simulation data and human data, and applied this method for evaluating the influence of scan time on the error of estimated BP in PET studies with [11C]raclopride. As a result, the reliability of kinetic parameter estimates in ROI analysis of human data was able to be deduced from the replicated data generated by bootstrap method. In [11C]raclopride studies, mean of estimated BP value did not change when the scan time varied from 30 to 90 min. However, variation of BP estimates became larger as the scan time became shorter. The standard deviation was under 1% when the scan time was longer than 60min. With the bootstrap method, the reliability of parameter estimates will be able to be estimated easily from only measured data, and this method is useful for the evaluation of optimal scan protocol.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 IEEE 2006 Nuclear Science Symposium and Medical Imaging Conference
発表年月日
日付 2006-11-04
日付タイプ Issued
戻る
0
views
See details
Views