CARBON ION THERAPY FOR OCULAR MELANOMA: PLANNING TWO-PORT TREATMENT

https://repo.qst.go.jp/records/68736
https://repo.qst.go.jp/records/68736
98a523fd-f643-4492-93a8-b2cfa3955364
Item type 会議発表用資料 / Presentation(1)
公開日 2006-10-24
タイトル
タイトル CARBON ION THERAPY FOR OCULAR MELANOMA: PLANNING TWO-PORT TREATMENT
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Koyama-Ito, Hiroko

× Koyama-Ito, Hiroko

WEKO 674545

Koyama-Ito, Hiroko

Search repository
Kanai, Tatsuaki

× Kanai, Tatsuaki

WEKO 674546

Kanai, Tatsuaki

Search repository
Tsuji, Hiroshi

× Tsuji, Hiroshi

WEKO 674547

Tsuji, Hiroshi

Search repository
Tsujii, Hirohiko

× Tsujii, Hirohiko

WEKO 674548

Tsujii, Hirohiko

Search repository
伊藤 浩子

× 伊藤 浩子

WEKO 674549

en 伊藤 浩子

Search repository
金井 達明

× 金井 達明

WEKO 674550

en 金井 達明

Search repository
辻 比呂志

× 辻 比呂志

WEKO 674551

en 辻 比呂志

Search repository
辻井 博彦

× 辻井 博彦

WEKO 674552

en 辻井 博彦

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose: To describe treatment planning techniques for two-port carbon ion therapy of ocular melanoma which was recently started with the intent to reduce incidence of radiation complications further than previously undertaken mono-port therapy since 2001.
Methods: We have used in house developed EyePlan for mono-port treatment, however its modification was impractical. In order to start two-port treatment sooner, an available treatment planning system (TPS), XiO-carbon, CMS Inc., (1) was tested if applicable. We evaluated that its precisions of geometrical tools and dose calculations are acceptable except for DRR calculations. Thus we adopted the TPS for two-port treatment.
A nozzle was prepared for use of horizontal beams. The details are reported separately in this meeting. Carbon ion broad beams with spread out Bragg peaks are used for irradiation. Beams are shaped using ridge filters (RF), apertures and range compensators. RFs were designed so as to deliver dose to cause uniform HSG cell kill within SOBP. Patient CT scans were taken at treatment position. Dose distributions are calculated with broad beam algorism using parameters determined by measurements and calculations. Precise DRR images for patient positioning are calculated using in house developed software (2).
Results: This TPS has been used for ten patients since October 2005. Among them, seven patients were treated with two ports due to lower dose to OAR; two fractions of vertical beams and three fractions of horizontal beams.
Conclusions: Treatment planning of ocular melanoma patients using a 3D conformal TPS has been acceptable for two-port therapy. However more geometrical resolutions are preferable in some of the software tools. Commonly used tools such as eye model display and image fusions of CT, MRI and fundus photograph are desirable and to be developed.
(1) H. Koyama-Ito: Carbon Ion Treatment Planning using a commercial RTP, Proc. ICCR, Seoul, 655-657, 2004.
(2) Sinichi Minohara et al., Patient Positioning of Intra-ocular Tumors using Online Portal X-ray Flat Panel Detector. PTCOG43, 2005
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 PTCOG45
発表年月日
日付 2006-10-11
日付タイプ Issued
戻る
0
views
See details
Views