ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Visualization of dose distribution on the endobronchial surface using virtual bronchoscopy in carbon ion radiotherapy

https://repo.qst.go.jp/records/68729
https://repo.qst.go.jp/records/68729
c30e4165-d468-4efd-bf2b-dc94c9939b31
Item type 会議発表用資料 / Presentation(1)
公開日 2006-10-23
タイトル
タイトル Visualization of dose distribution on the endobronchial surface using virtual bronchoscopy in carbon ion radiotherapy
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Baba, Masayuki

× Baba, Masayuki

WEKO 674504

Baba, Masayuki

Search repository
Minohara, Shinichi

× Minohara, Shinichi

WEKO 674505

Minohara, Shinichi

Search repository
Sugane, Toshio

× Sugane, Toshio

WEKO 674506

Sugane, Toshio

Search repository
Nakajima, Mio

× Nakajima, Mio

WEKO 674507

Nakajima, Mio

Search repository
Imai, Reiko

× Imai, Reiko

WEKO 674508

Imai, Reiko

Search repository
Kandatsu, Susumu

× Kandatsu, Susumu

WEKO 674509

Kandatsu, Susumu

Search repository
Miyamoto, Tadaaki

× Miyamoto, Tadaaki

WEKO 674510

Miyamoto, Tadaaki

Search repository
Kamada, Tadashi

× Kamada, Tadashi

WEKO 674511

Kamada, Tadashi

Search repository
Tsujii, Hirohiko

× Tsujii, Hirohiko

WEKO 674512

Tsujii, Hirohiko

Search repository
et.al

× et.al

WEKO 674513

et.al

Search repository
馬場 雅行

× 馬場 雅行

WEKO 674514

en 馬場 雅行

Search repository
蓑原 伸一

× 蓑原 伸一

WEKO 674515

en 蓑原 伸一

Search repository
須金 紀雄

× 須金 紀雄

WEKO 674516

en 須金 紀雄

Search repository
中嶋 美緒

× 中嶋 美緒

WEKO 674517

en 中嶋 美緒

Search repository
今井 礼子

× 今井 礼子

WEKO 674518

en 今井 礼子

Search repository
神立 進

× 神立 進

WEKO 674519

en 神立 進

Search repository
宮本 忠昭

× 宮本 忠昭

WEKO 674520

en 宮本 忠昭

Search repository
鎌田 正

× 鎌田 正

WEKO 674521

en 鎌田 正

Search repository
辻井 博彦

× 辻井 博彦

WEKO 674522

en 辻井 博彦

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose: To estimate effects of carbon-ion radiotherapy on endobronchial tumor or epithelium, we developed the visualizing application of planning dose distribution on virtual bronchoscopic images. The comparison of tissue responses by actual bronchoscopic findings and planning dose distribution on virtual bronchoscopy would be important to evaluate the accuracy of irradiation and the dose response. We developed the software to superimpose the color map of planning dose distribution on virtual bronchoscopic images.
Methods: Respiratory gated CT images using multi-detector CT scanner are taken for the patient of lung cancer. Treatment planning is performed to a set of gated CT images using a HIPLAN. Then the isocenter information file, dose distribution files at each filed and a set of CT volume file are inputted to application software of virtual bronchoscopy. We developed this application based on commercial software of virtual bronchoscopy (AZE Ltd. Virtual Place Advance Plus). Following the geometrical adjustment and interpolation with CT images and dose distribution, the 3-dimensional voxel data set is reconstructed. Each voxel is defined as x, y, z, CT value, and dose at each field. Using volume rendering technique, virtual bronchoscopic images are reconstructed. In proportion as the dose, pixels at endobronchial surface are visualized by color map.
Results: Planning dose distribution at each filed or total filed was visualized on the endobronchial surface of virtual bronchoscopy, and was simultaneously displayed on axial, sagittal and coronal multiplanar reconstruction CT images, too. When the observing point on virtual bronchoscopy is moved in the 3-dimensional bronchoscopic image by interactive exploration, the bronchoscopic image with dose map was obtained in real-time. On each cross-sectional CT image, the location and the direction of the observing point were simultaneously displayed and moved in association with the bronchoscopic image. Thus we can observe the dose distribution at any point with any angle on virtual endobronchial surface.
Conclusions: We developed the unique dose distribution display system on virtual bronchoscopy. This system is emerging as a useful approach for evaluation of bronchial dose response in comparison of actual bronchoscopic images.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 Particle Therapy Co-Operative Group PTCOG 45
発表年月日
日付 2006-10-13
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:22:47.811391
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3