Optimization of raster scanning irradiation taken account of exposure during beam spot transition

https://repo.qst.go.jp/records/68722
https://repo.qst.go.jp/records/68722
d625455a-3610-4108-b51f-182c0c74507f
Item type 会議発表用資料 / Presentation(1)
公開日 2006-10-17
タイトル
タイトル Optimization of raster scanning irradiation taken account of exposure during beam spot transition
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Inaniwa, Taku

× Inaniwa, Taku

WEKO 674451

Inaniwa, Taku

Search repository
稲庭 拓

× 稲庭 拓

WEKO 674452

en 稲庭 拓

Search repository
抄録
内容記述タイプ Abstract
内容記述 In order to make the most use of the merits of heavy-ions in a cancer treatment,at present, the raster scanning is an ieal irradiation technique at least for static tumor.Therefore,a project to construct new treatment rooms dedicated to this irradiation technique has been started at Heavy Ion Medical Accelerator in Chiba(HIMAC) since this April. In this new irradiation facility,we intend to treat not only the static tumor but also the moving tumor in cooperation with the gated irradiation(GI)and rescanning(RS)method.In our scanning scheme 'raster scanning',contrary to the strict sense of spot scanning irradiation,the beam delivery is not switched-off during the transitiontime from one spot to the next.Therefore,in this scheme,a'transition-exposure',which means the undesired dose deposition during the beam spot transition,is unavoidable.This effect can be neglected if the beam intensity is quite low e.g.10^6^particles/s and the magnetic scanning velocity is about 5-10mm/ms.However,the beam intensity as high as ~10^8^particles/s is required to shorten the treatment time,e.g.5min,and reduce the stress put on a patient due to prolonged fixation,especially in the treatment of a moving tumor with GI and RS.In this case,the transition-exposure cannot be neglected and will make a severe distortion on the dose distribution in a tumore molume.To overcome this problem, we have developed the optimization method that includes the effect of the transition-exposure in optimization calculation of spot beam distribution,and showed the effectiveness of this method with computer simulation.Our optimization caluclation is based on the limted-memory BFGS algorithm(L-BFGS).The transition-exposure depends on the magnetic scanning velocity(each x-andy-direction)and beam intensity and modeled to be deposited between two successive beam spots in our optimization calculation.With the optimized spot beam distribution,flat biological dose distribution over the target volume could be achieved through our simulation for several targets with different shapes and/or sizes. The details of our simulation results will be presented in the meeting.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 PTCOG45
発表年月日
日付 2006-10-11
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:22:52.739643
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3