WEKO3
-
RootNode
アイテム
Inter-crystal scatter identification for a depth-sensitive detector using support vector machine for small animal PET
https://repo.qst.go.jp/records/68625
https://repo.qst.go.jp/records/68625909511d7-fcbe-4298-94ee-8e0464fc1ceb
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2006-08-18 | |||||
タイトル | ||||||
タイトル | Inter-crystal scatter identification for a depth-sensitive detector using support vector machine for small animal PET | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Yoshida, Eiji
× Yoshida, Eiji× Kitamura, Keishi× Kimura, Yuichi× Nishikido, Fumihiko× Shibuya, Kengo× Yamaya, Taiga× Murayama, Hideo× 吉田 英治× 北村 圭司× 木村 裕一× 錦戸 文彦× 澁谷 憲悟× 山谷 泰賀× 村山 秀雄 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | In a conventional PET detector, detected events are projected to 2D position histogram with Anger calculation for a crystal identification. However, the measured histogram is affected by inter-crystal scatterings (ICS) which occur in a whole detector. Peaks with projected each crystal in the histogram are blurred, and it causes ICS's mispositioning. A depth of interaction (DOI) detector has been developed for the small animal PET scanner: jPET-RD. This DOI detector uses 32 x 32 crystals with four layers and a 256-channel multi-anode flat panel photomultiplier tube (FP-PMT) was developed by Hamamatsu Photonics K.K. Each crystal element is 1.45 x 1.45 x 4.5 mm3. The FP-PMT has a large detective area (49 x 49 mm2) and small anode pitch (3.04 mm). Therefore, the FP-PMT can extensively trace the behavior of incident gamma rays in the crystals including ICS. We therefore propose a novel method for ICS estimation using a statistical pattern recognition based on the support vector machine (SVM). In this study, we applied the SVM for discriminating photoelectric events from ICS events generated from multiple-anode outputs. The SVM was trained by uniform irradiation events generated from a detector simulator using Monte Carlo calculation. Initial result of ICS identification is about 78 % for non-training data. This method can archive a true subtraction of ICS from measured events, and it is also useful for random correction in PET. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 1st European Conference on Molecular Imaging Technology | |||||
発表年月日 | ||||||
日付 | 2006-05-12 | |||||
日付タイプ | Issued |
Share
Cite as
Yoshida, Eiji, Kitamura, Keishi, Kimura, Yuichi, Nishikido, Fumihiko, Shibuya, Kengo, Yamaya, Taiga, Murayama, Hideo, 吉田 英治, 北村 圭司, 木村 裕一, 錦戸 文彦, 澁谷 憲悟, 山谷 泰賀, 村山 秀雄, 2006, Inter-crystal scatter identification for a depth-sensitive detector using support vector machine for small animal PET.