A REAL TIME EYE-MOTION TRACKING SYSTEM FOR IMAGE GUIDED RADIOTHERAPY OF INTRA-OCULAR TUMOR

https://repo.qst.go.jp/records/68305
https://repo.qst.go.jp/records/68305
66a031cf-71c9-47cf-9b25-7830aed111b3
Item type 会議発表用資料 / Presentation(1)
公開日 2006-01-19
タイトル
タイトル A REAL TIME EYE-MOTION TRACKING SYSTEM FOR IMAGE GUIDED RADIOTHERAPY OF INTRA-OCULAR TUMOR
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Minohara, Shinichi

× Minohara, Shinichi

WEKO 670585

Minohara, Shinichi

Search repository
et.al

× et.al

WEKO 670586

et.al

Search repository
蓑原 伸一

× 蓑原 伸一

WEKO 670587

en 蓑原 伸一

Search repository
抄録
内容記述タイプ Abstract
内容記述 <Purpose> During the irradiation of the intra-ocular tuomur, the patient must be capable to co-operate and to maintain to a fixed stare at a particular angle to concentrate the dose on the target. To increase the accuracy and reproducibility of the gaze and to avoid the error of dose distribution resulted from eye-motion, we developed a system to track the eye-motion in real time and to irradiate with the gating technique. <Methods> Using infrared video image around the patient eye, the pupil and the Purkinje which is a reflection from the surface of cornea are detected by image processing. A set of these two points is applied on the eye-ball model and the angle of gaze is estimated. If the direction of gaze is moved to outside of permitted area by the rotary motion of eye ball or by the eyelid, the gate signal to beam-off is generated, and the irradiation is automatically turned off.<Results> In preliminary study using an artificial eye, our system detected the pupil position with the accuracy of less than 0.2 mm. In subjects, the minor fluctuation about 1.8 degree of the gaze direction was observed. This variation was almost equivalent to the motion of 0.4 mm on the eye surface. The total response time from the change of gaze to beam-off was less than 67 milliseconds.<Discussions> The accuracy of developed system would be enough clinically, and this will support the safety irradiation of ocular tumour and the quantitative verification of the patient gaze.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 4th Shinji Takahashi Memorial International Workshop on 3D-CRT
発表年月日
日付 2004-12-12
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:27:42.568084
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3