ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Experimental study on the beam characteristics using an amplitude modulation wobbler system for heavy-ion radiotherapy

https://repo.qst.go.jp/records/68291
https://repo.qst.go.jp/records/68291
075f25ed-b6fa-43f8-bdce-63758a51f0ae
Item type 会議発表用資料 / Presentation(1)
公開日 2005-12-19
タイトル
タイトル Experimental study on the beam characteristics using an amplitude modulation wobbler system for heavy-ion radiotherapy
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Yonai, Shunsuke

× Yonai, Shunsuke

WEKO 670436

Yonai, Shunsuke

Search repository
et.al

× et.al

WEKO 670437

et.al

Search repository
米内 俊祐

× 米内 俊祐

WEKO 670438

en 米内 俊祐

Search repository
抄録
内容記述タイプ Abstract
内容記述 In the Heavy Ion Medical Accelerator in Chiba (HIMAC) at the National Institute of Radiological Sciences (NIRS), over 2000 patients have been treated with carbon beams and good results have been yielded. However, we must overcome a problem of the construction cost to popularize the heavy-ion radiotherapy. Therefore, we are proceeding with studies to realize more compact facilities for the radiotherapy.
In these studies, the length of an irradiation port is required to scale down to half of that in HIMAC. However, the wobbler-scatterer system which is used in HIMAC at present, can not be directly applicable because the residual range would be severely reduced by thicker scatterer required for the short irradiation port. Therefore, an amplitude modulation wobbler system with a thin scatterer has been studied to overcome the problem. Especially, we have proposed the spiral-wobbler system which produces circular irradiation fields up to 22 cm in diameter using a fixed beam size of ~25 mm. This system also has advantages of its simple design and high efficiency of beam use as compared with the conventional wobbler-scatterer system.
In this meeting, we report about the beam characteristics by the spiral-wobber system with experimental studies. Since the two orthogonally-bending magnets of the system are driven by independent power supplies with programmable waveforms, the system can flexibly deliver various wobbling patterns and the possibilities of other wobbling methods are also discussed.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 Particle Therapy Co-Operative Group,PTCOG43
発表年月日
日付 2005-12-14
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:27:52.092565
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3