ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

The jPET-D4: Simple and reliable construction method for 4-layer DOI crystal blocks

https://repo.qst.go.jp/records/68227
https://repo.qst.go.jp/records/68227
68e1cd2f-fdf9-41b0-adff-81b86a79a7f2
Item type 会議発表用資料 / Presentation(1)
公開日 2005-11-09
タイトル
タイトル The jPET-D4: Simple and reliable construction method for 4-layer DOI crystal blocks
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Ono, Yusuke

× Ono, Yusuke

WEKO 669874

Ono, Yusuke

Search repository
小野 裕介

× 小野 裕介

WEKO 669875

en 小野 裕介

Search repository
抄録
内容記述タイプ Abstract
内容記述 The jPET-D4 detector module consists of four layers of 16 x 16 Gd2SiO5 (GSO) crystals and 256 channel flat panel position sensitive photomultiplier tube (256ch FP-PMT). Each crystal element is in dimensions of 2.9mm x 2.9mm x 7.5(or 7.2) mm and crystal identification in the crystal block offers detected location 3-demensionaly. Two kinds of GSO crystals having different Ce dopant concentration are used in the upper and lower two layers in order to distinguish these layers by pulse shape discrimination. Proper reflector insertion in the crystal block then enables to identify crystals of detection in each two layers.
For mass production of the depth of Interaction (DOI) crystal block composed of 1024 crystal elements with proper reflector arrangement, we designed appropriate tools which promote simple construction as well as uniform configuration. The four of crystal layer assembled with the tool are coupled in depth by RTV rubber and adjusted external size with another tool. The construction took only 3 hours per one crystal block. To estimate reliability of the construction method, uniformity of pulse shape discrimination, energy resolution and light output were studied on 120 crystal blocks actually constructed in the method.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 Nuclear Science Symposium & Medical Imaging Conference
発表年月日
日付 2005-10-29
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:28:36.252501
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3