IMAGING OF THE CHOROIDAL MALIGNANT MELANOMA USING L-[METHYL-11-C]METHIONINE PET(MET-PET).

https://repo.qst.go.jp/records/68006
https://repo.qst.go.jp/records/68006
0cbfa061-296b-43ac-b3a8-d5f43e911c2a
Item type 会議発表用資料 / Presentation(1)
公開日 2005-01-28
タイトル
タイトル IMAGING OF THE CHOROIDAL MALIGNANT MELANOMA USING L-[METHYL-11-C]METHIONINE PET(MET-PET).
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Tamura, Katsumi

× Tamura, Katsumi

WEKO 667899

Tamura, Katsumi

Search repository
Yoshikawa, Kyosan

× Yoshikawa, Kyosan

WEKO 667900

Yoshikawa, Kyosan

Search repository
Sagou, Kenji

× Sagou, Kenji

WEKO 667901

Sagou, Kenji

Search repository
Mizoe, Junetsu

× Mizoe, Junetsu

WEKO 667902

Mizoe, Junetsu

Search repository
Tsujii, Hirohiko

× Tsujii, Hirohiko

WEKO 667903

Tsujii, Hirohiko

Search repository
et.al

× et.al

WEKO 667904

et.al

Search repository
田村 克巳

× 田村 克巳

WEKO 667905

en 田村 克巳

Search repository
吉川 京燦

× 吉川 京燦

WEKO 667906

en 吉川 京燦

Search repository
佐合 賢治

× 佐合 賢治

WEKO 667907

en 佐合 賢治

Search repository
溝江 純悦

× 溝江 純悦

WEKO 667908

en 溝江 純悦

Search repository
辻井 博彦

× 辻井 博彦

WEKO 667909

en 辻井 博彦

Search repository
抄録
内容記述タイプ Abstract
内容記述 Objectives:L-[methyl-11-C] methionine(11C-MET)is a tracer for PET that can be use to assess metabolism of amino acid in tumor cells.Methionine is needed for protein synthesis,and in cancer cells the rate of protein synthesis and transmethylation is high.The orbita is close to brain,and 11C-MET is less accumulated in the normal brain compared with 18F-FDG. Therefore,11C-MET is less influenced by the accumulation of the brain than 18F-FDG.There have not been PET studies concerned with the choroidal malignant melanoma.The purpose of this study is to assess the ability of 11C-MET PET to evaluate choroidal malignant melanoma.
Methods:We studied consecutive 31 patients with the choroidal malignant melanoma who had been referred to our hospital for carbon ion beam therapy in 2001-2003.14 patients were female and 17 patients were male. The average patient age was 56.9 years (range 28 to 85).We evaluated the lesion semiquantitatively on the basis of the Tumor-To-Brain Ratio (TBR) obtained as follows.The regions of interest (ROI) were placed in the choroidal primary lesion,including the highest uptake area (circle ROI, 4x4 pixels) and bilateral cerebellum (or occipital lobe) areas on the same slice.TBR was calculated by dividing the mean radioactivity of the tumor ROI by that of the bilateral cerebellum (or occipital lobe) ROI.
Results:The size of choroidal lesion averraged 12.7mm (土3.29 SD) on the MRI,ranged 5 to 18mm.30 choroidal lesions were positive (96.8%) on the static image of 11C-MET-PET.The TBR averaged 1.76 (土0.69 SD),ranged 0.38 to 3.17.TBR and tumor size of only one negative lesion on 11C-MET-PET was 0.38 and 5mm respectively.There was no correlation between TBR and tumor size (R2=0.40).
Conclusions:Except the lachrymal gland,there is no tissue in the orbital cavity that 11C-MET is normally accumulated. 11C-MET-PET has shown good detectability (96.8%) for the choroidal malignant melanoma on the static image.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 Society of nuclear medicine's 51st. annual meeting
発表年月日
日付 2004-06-25
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:31:12.267860
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3