Development of Droplet-PIXE system for Environmental Monitoring Samples

https://repo.qst.go.jp/records/68004
https://repo.qst.go.jp/records/68004
2726e0f9-542e-476e-9750-087300662012
Item type 会議発表用資料 / Presentation(1)
公開日 2005-01-25
タイトル
タイトル Development of Droplet-PIXE system for Environmental Monitoring Samples
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Imaseki, Hitoshi

× Imaseki, Hitoshi

WEKO 667869

Imaseki, Hitoshi

Search repository
Ishikawa, Takahiro

× Ishikawa, Takahiro

WEKO 667870

Ishikawa, Takahiro

Search repository
Iso, Hiroyuki

× Iso, Hiroyuki

WEKO 667871

Iso, Hiroyuki

Search repository
Shinomiya, Takayuki

× Shinomiya, Takayuki

WEKO 667872

Shinomiya, Takayuki

Search repository
Hamano, Tsuyoshi

× Hamano, Tsuyoshi

WEKO 667873

Hamano, Tsuyoshi

Search repository
Yukawa, Masae

× Yukawa, Masae

WEKO 667874

Yukawa, Masae

Search repository
今関 等

× 今関 等

WEKO 667875

en 今関 等

Search repository
石川 剛弘

× 石川 剛弘

WEKO 667876

en 石川 剛弘

Search repository
四野宮 貴幸

× 四野宮 貴幸

WEKO 667877

en 四野宮 貴幸

Search repository
濱野 毅

× 濱野 毅

WEKO 667878

en 濱野 毅

Search repository
湯川 雅枝

× 湯川 雅枝

WEKO 667879

en 湯川 雅枝

Search repository
抄録
内容記述タイプ Abstract
内容記述 Behaviour of radionuclides in the environment and organisms has been investigated to evaluate the radiation effect on human using stable isotopes using PIXE analysis at the PASTA facilities in the NIRS. Since some of the environmental monitoring samples are in the liquid state, pre-treatment of the samples such as filtration, drying and solidification are necessary prior to the PIXE analysis. During sample preparation process, there may be loss of element due to sublimation or evaporation that must be taken care for quantitative analysis. To avoid such problems, we have developed a suitable dropletPIXE system. It is based on the following points,(i) development of equipment with a good stability to supply a droplet of good reproducibility, (ii) optimisation of all equipments that includes a stable beam line (proton, 2.8MeV) and (iii) to evaluate irradiation dose for quantitative analysis. It will be advantageous to many researchers since it is very simple and save time during the sample preparation. However, there are some disadvantages in the detection range compared to conventional PIXE. The droplet-PIXE system has been applied to a few case studies. Limits of detection with or without any chemical preparation and its superiority or advantages over other PIXE system will be discussed in this paper. Application of the droplet-PIXE system can be expanded in future to other possibilities.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 5th International Symposium on BioPIXE
発表年月日
日付 2005-01-21
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:31:13.667383
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3