INCORPORATING ORGAN MOTION UNCERTAINTIES INTO CARBON ION TREATMENT PLANNING

https://repo.qst.go.jp/records/67987
https://repo.qst.go.jp/records/67987
62ee7b26-29ab-4d14-aa25-08d37a560213
Item type 会議発表用資料 / Presentation(1)
公開日 2004-12-17
タイトル
タイトル INCORPORATING ORGAN MOTION UNCERTAINTIES INTO CARBON ION TREATMENT PLANNING
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Koyama-Ito, Hiroko

× Koyama-Ito, Hiroko

WEKO 667705

Koyama-Ito, Hiroko

Search repository
et.al

× et.al

WEKO 667706

et.al

Search repository
伊藤 浩子

× 伊藤 浩子

WEKO 667707

en 伊藤 浩子

Search repository
抄録
内容記述タイプ Abstract
内容記述 <Purpose> This study reports and evaluates treatment planning including organ motion uncertainties for three-dimensional conformal therapy of lung cancer with respiration gated carbon ion broad beams. The distal margins were added by radiological path length.
<Materials and Methods> During treatment a patient is irradiated while the respiration signal from monitor placed on patient skin is close to end expiration phase of free breathing. Planning CT scans are taken gated with the same signal. To the CTV delineated on planning CT slices, margins for uncertainties in tumor movements are added based on fluoroscopy examinations typically 10 mm in cranial and 5 mm in caudal direction. The range compensator (RC) is designed for PTV that includes these margins under the assumption that the lung including tumor moves in cranial-caudal (CC) direction sliding along the chest wall.
<Results> Dose distributions are calculated for different tumor locations. Within the model of lung motion, CTV dose coverage is observed although the irradiated lung volume increases in enhanced degree due to the low electron density of lung.
<Discussions> The uncertainties in tumor motion are determined from clinical experience in fluoroscopy observations prior to irradiations. In order to reduce motion margins further, more accurate tumor position monitor is required. The effect of chest wall movement remains for future study with 4-D CT.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 4th Shinji Takahashi Memorial International Workshop on 3D-CRT
発表年月日
日付 2004-12-12
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:31:24.842710
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3