Preliminary Performance Evaluation of the Prototype System for a Brain DOI-PET Scanner: jPET-D4

https://repo.qst.go.jp/records/67915
https://repo.qst.go.jp/records/67915
b87d7af2-aae3-4ea7-bf0b-f95b3b942f05
Item type 会議発表用資料 / Presentation(1)
公開日 2004-10-27
タイトル
タイトル Preliminary Performance Evaluation of the Prototype System for a Brain DOI-PET Scanner: jPET-D4
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Yamaya, Taiga

× Yamaya, Taiga

WEKO 667079

Yamaya, Taiga

Search repository
et.al

× et.al

WEKO 667080

et.al

Search repository
山谷 泰賀

× 山谷 泰賀

WEKO 667081

en 山谷 泰賀

Search repository
抄録
内容記述タイプ Abstract
内容記述 A high-performance brain PET scanner, jPET-D4, which provides depth-of-interaction (DOI) information, is under development. The scanner is designed to achieve not only high spatial resolution but also high scanner sensitivity with the DOI information obtained from multi-layered thin crystals. The scanner has 5 rings of 24 detector blocks each, and the detector block consists of 1,024 GSO crystals of 2.9mm x 2.9mm x 7.5mm, which are arranged in 4 layers of 16 x 16 arrays. At this stage, a pair of detector blocks and a coincidence circuit has been assembled into an experimental prototype gantry. In this paper, as a preliminary experiment, we have investigated the performance of the jPET-D4's inherent spatial resolution and noise characteristics using the prototype system. Spatial resolution and background noise were measured by using a line source and a uniform cylinder phantom respectively. To avoid systematic error and reduce computational cost in image reconstruction, the DOI compression (DOIC) method followed by the ML-EM with accurate system modeling, that we have previously proposed, was applied. Experimental results showed that the jPET-D4 achieves less than 3mm spatial resolution over the field-of-view. Trade-off results between spatial resolution and background noise also promise an excellent performance of the scanner.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 IEEE 2004 Nuclear Science Symposium and Medical Imaging Conference
発表年月日
日付 2004-10-22
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:32:15.360387
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3