Development of the high resolution electron beam profile monitor for medical use X-band linac

https://repo.qst.go.jp/records/67844
https://repo.qst.go.jp/records/67844
01f4c230-dd08-4204-944e-27a85a759598
Item type 会議発表用資料 / Presentation(1)
公開日 2004-08-09
タイトル
タイトル Development of the high resolution electron beam profile monitor for medical use X-band linac
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Sakamoto, Fumito

× Sakamoto, Fumito

WEKO 666532

Sakamoto, Fumito

Search repository
坂本 文人

× 坂本 文人

WEKO 666533

en 坂本 文人

Search repository
抄録
内容記述タイプ Abstract
内容記述 Compact hard X-ray source using the X-band linear accelerator to which is developed in Nuclear Engineering Research Laboratory the University of Tokyo makes beam size 100micrometer pulse laser and an electronic beam collide, and generates X-rays by Compton scattering. In order to collide a laser electronic beam efficiently, the beam profile monitor that can measure a beam profile with sufficient accuracy is indispensable. As a beam profile monitor which has resolution between the altitude which can measure 100 micro meters, it is focused on Wire scanner, OTR(Optical Transition Radiation) monitor and Screen monitor(alumina ceramics), and the research and development are done. Moreover, since it has the angular distribution decided by the energy of electron beam also besides measuring a beam profile. The angular distribution of optical transition radiation is asking for the electron beam dispersion angle and beam size in the beam waist simultaneously, it can expect measuring beam emittance. The measurement comparison with the QUAD scan method shows the emittance measurement possibility. If this measurement method is success the emittance measurement is done only 1 shot measurement. Supposing the X-band linear accelerator, some verification experiments are performed with S-band linear accelerator (E=20MeV) in this institution. From last experiment, we have observed the blots of Screen monitor about 75 micro meters. From the thickness of the screen was 100 micro meters, we can determine the blots of the screen monitor are depend on the thickness of screen. So the screen monitor cannot measure the beam size less than 100 micro meters. Measuring the beam profile using these three (OTR, Wire Scanner, Screen monitor) beam profile monitors repeatedly, we have achieved the resolution within statistically 10 micrometers. From the experiment of the OTR angular distribution measurement, we have achieved to measure the electron beam energy within the resolution 1MeV and the beam emittance was measured about 20 [pi mm mrad], this result shows the agreement with the result from QUAD scan method. In this poster presentation, we report the result of the verification experiments.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 Korea-Japan Seminar on Advanced Utilization of Particle Accelerator
発表年月日
日付 2004-07-30
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:33:05.074486
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3