ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Bioaccumulation of technetium by bacterial community in water covering a rice paddy field soil

https://repo.qst.go.jp/records/67761
https://repo.qst.go.jp/records/67761
06756782-50cb-49d6-b095-751235268650
Item type 会議発表用資料 / Presentation(1)
公開日 2004-04-15
タイトル
タイトル Bioaccumulation of technetium by bacterial community in water covering a rice paddy field soil
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Ishii, Nobuyoshi

× Ishii, Nobuyoshi

WEKO 665877

Ishii, Nobuyoshi

Search repository
Tagami, Keiko

× Tagami, Keiko

WEKO 665878

Tagami, Keiko

Search repository
石井 伸昌

× 石井 伸昌

WEKO 665879

en 石井 伸昌

Search repository
田上 恵子

× 田上 恵子

WEKO 665880

en 田上 恵子

Search repository
抄録
内容記述タイプ Abstract
内容記述 Bioaccumulation of technetium (Tc) by bacterial community in water body covering a rice paddy field soil is studied to gain insight on the behavior of Tc in agricultural ecosystem. The radioactive tracer, pertechnetate (95mTcO4-), was added to aqueous solution collected from a waterlogged paddy field soil. The solution was incubated statically at 25 under dark conditions. Up to 80% of the total 95mTc was removed from the solution for 4 days. However, little 95mTc was removed;
from both a cell-free filtrate solution and a filtrate mixed with autoclaved cell particles at day 4. The maximum removal of the 95mTc, about 85%, was achieved
by addition of nutrients to the solution. When activities of bacteria inhibited
by addition of antibiotics, only 23% of the 95mTc was removed. Addition of cycloheximide, however, did not affect on the removal of the 95mTc. These results indicate that the bacterial community living in water body accumulates Tc. In order to determine the effects of oxygen level on Tc removal, bacterial communities were incubated under aerobic and anaerobic conditions. It is reasonable that the
bacterial community cultured under anaerobic conditions removed 80% of Tc from the solution, however, interestingly, the bacterial community grown under aerobic conditions also showed Tc removal of 30%. The result implies that aerobic bacterial communities have a potential for removing Tc from aqueous solutions.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 International Conference on Protection of the Environment from the Effects of Ionizing Radiation
発表年月日
日付 2003-10-10
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:34:01.321450
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3