WEKO3
アイテム
TEST RESULTS OF RF CAVITY AND POWER AMPLIFIER FOR COMPACT MEDICAL PROTON SYNCHROTRON
https://repo.qst.go.jp/records/67735
https://repo.qst.go.jp/records/67735a214fd7a-9e7d-4b25-bcaf-dbb72c22ad8b
| Item type | 会議発表用資料 / Presentation(1) | |||||
|---|---|---|---|---|---|---|
| 公開日 | 2004-03-31 | |||||
| タイトル | ||||||
| タイトル | TEST RESULTS OF RF CAVITY AND POWER AMPLIFIER FOR COMPACT MEDICAL PROTON SYNCHROTRON | |||||
| 言語 | ||||||
| 言語 | eng | |||||
| 資源タイプ | ||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
| 資源タイプ | conference object | |||||
| アクセス権 | ||||||
| アクセス権 | metadata only access | |||||
| アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
| 著者 |
Fan
× Fan× 方 志高 |
|||||
| 抄録 | ||||||
| 内容記述タイプ | Abstract | |||||
| 内容記述 | A compact proton synchrotron with a circumference of 11.9m is being developed for the medical radiotherapy. The synchrotron acceleration system is required to be of a wide bandwidth with the frequency sweeping from 1.64MHz to 14.26MHz, and a high gradient with the maximum acceleration voltage of 20kV. The prototype of the rf acceleration system has been developed. The rf cavity consists of 2 cells loaded with 4 high-permeability magnetic alloy cores in each cell, and a push-pull power amplifier with two 35kW tetrode tubes is used to drive the 2 cells of the cavity in parallel. The test results and design values of the rf cavity and power amplifier will be presented. | |||||
| 会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
| 内容記述タイプ | Other | |||||
| 内容記述 | APAC'04 Organizing Committee | |||||
| 発表年月日 | ||||||
| 日付 | 2004-03-26 | |||||
| 日付タイプ | Issued | |||||