ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

THE DESIGN AND IMPLEMENTATION OF A HEAVY ION THERAPY DATABASE

https://repo.qst.go.jp/records/67708
https://repo.qst.go.jp/records/67708
ecf358ce-cc7c-4d60-93fd-db016cdc4796
Item type 会議発表用資料 / Presentation(1)
公開日 2004-01-21
タイトル
タイトル THE DESIGN AND IMPLEMENTATION OF A HEAVY ION THERAPY DATABASE
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Ito, Hiroko

× Ito, Hiroko

WEKO 665424

Ito, Hiroko

Search repository
伊藤 浩子

× 伊藤 浩子

WEKO 665425

en 伊藤 浩子

Search repository
抄録
内容記述タイプ Abstract
内容記述 A database system of carbon ion therapy to be used for the analysis of planning data as well as treatment records has been designed and implemented. This database will give investigators access to the imaging and character data since the start of the clinical trials June 1994.
A schematic diagram of the system is shown in Fig.1. The database is created on an Oracle relational database management system running on a Sun workstation. We implemented a DICOM v3.0 (1) including radiotherapy extensions. The MergeCom Toolkit (Merge Technologies Inc., Milwaukee, U.S.A.) was used. Data were mapped to DICOM standard objects; however, limited numbers of private attributes were introduced for ion therapy specific objects since ion therapy was not supported yet.
All the saved planning data and treatment records of 1200 patients have been loaded into the database with a software tool. In routine use, planning data and treatment records saved in storage disks are loaded into the database on-line every night. Besides this, GUI tools used to load data manually as well as to edit loaded data are prepared.
User can access database with standard WWW browser to search and retrieve information. A DICOM RT viewer has been developed to view and retrieve RT images, dose distributions and structure set. The system has been fully tested.
発表年月日
日付 2002-05-31
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:34:37.287696
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3