ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Development of Dual-Energy X-ray CT using Synchrotron Radiation

https://repo.qst.go.jp/records/67704
https://repo.qst.go.jp/records/67704
a32f9833-5638-4ec6-ba31-d4b5fff82738
Item type 会議発表用資料 / Presentation(1)
公開日 2004-01-15
タイトル
タイトル Development of Dual-Energy X-ray CT using Synchrotron Radiation
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Torikoshi, Masami

× Torikoshi, Masami

WEKO 665390

Torikoshi, Masami

Search repository
取越 正己

× 取越 正己

WEKO 665391

en 取越 正己

Search repository
抄録
内容記述タイプ Abstract
内容記述 Monochromatic x-ray CT at two different energies provides information about electron density (re) of human tissue without ambiguity due to the beam hardening effect. This information makes the treatment planning for heavy-ion radiotherapy more precise. We have started a feasibility study on the dual-energy x-ray CT by using synchrotron radiation. We developed a linear scanning CT system in order to clarify what precision in the measurement was achieved. The experiments were carried out using monochromatic x-rays of 40, 70 and 80 keV. Comparison of measured electron densities with the theoretical values proved that these values were in agreement in 0.9 % on average. We have constructed the dual-energy X-ray CT system with a two-dimensional scintillator array to take images in a short time. At present, it has been partially found that the 2D system measures the electron densities in the precision of about 1 %.Effective atomic numbers (Zeff) are obtained as well from the dual-energy x-ray CT. The tomographic image based on each of re and Zeff presents a different feature of a material, and its contrast differs from that in a conventional CT image. Both the images of a sample of kidney of a pig are shown for example. The left lower is the re image, and the right lower is that of Zeff. The renal pelvis is clearly distinguished from the renal medulla. Some dark spots in the left drawing, which are inferred to be blood vessels, are invisible in the right one. It tells that the spots consist of similar elements of the renal medulla while the electron densities are abnormally low. The feature of the images may help distinguish more clearly tissues or organs with aid of difference contrast from the conventional CT images.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 ポータブルシンクロトロン放射光とその応用に関する国際会議
発表年月日
日付 2004-01-14
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:34:40.880787
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3