ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Evaluation of image reconstruction methods for improving resolution in radial direction with PET

https://repo.qst.go.jp/records/67404
https://repo.qst.go.jp/records/67404
902f4d29-f418-4f2c-86cf-eb7465fc4c7d
Item type 会議発表用資料 / Presentation(1)
公開日 2003-07-08
タイトル
タイトル Evaluation of image reconstruction methods for improving resolution in radial direction with PET
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Yamakawa, Keisuke

× Yamakawa, Keisuke

WEKO 662539

Yamakawa, Keisuke

Search repository
Kitamura, Keishi

× Kitamura, Keishi

WEKO 662540

Kitamura, Keishi

Search repository
Uemura, Koji

× Uemura, Koji

WEKO 662541

Uemura, Koji

Search repository
Toyama, Hinako

× Toyama, Hinako

WEKO 662542

Toyama, Hinako

Search repository
Haneishi, Hideaki

× Haneishi, Hideaki

WEKO 662543

Haneishi, Hideaki

Search repository
Murayama, Hideo

× Murayama, Hideo

WEKO 662544

Murayama, Hideo

Search repository
Uchiyama, Akihiko

× Uchiyama, Akihiko

WEKO 662545

Uchiyama, Akihiko

Search repository
山川 恵介

× 山川 恵介

WEKO 662546

en 山川 恵介

Search repository
北村 圭司

× 北村 圭司

WEKO 662547

en 北村 圭司

Search repository
上村 幸司

× 上村 幸司

WEKO 662548

en 上村 幸司

Search repository
外山 比南子

× 外山 比南子

WEKO 662549

en 外山 比南子

Search repository
羽石 秀昭

× 羽石 秀昭

WEKO 662550

en 羽石 秀昭

Search repository
村山 秀雄

× 村山 秀雄

WEKO 662551

en 村山 秀雄

Search repository
抄録
内容記述タイプ Abstract
内容記述 The in-plane resolution is known to decrease depending on the distance from the center in a PET image. Many methods to improve the spatial resolution have been proposed by many authors with hardware or software. The purpose of this work was to improve the in-plane resolution of PET images without complex calculation and special hardware. We have adopted the detector response function (DRF) changing in the width at the distance from the center to reconstruct PET images. We have evaluated our method for the computer simulated phantom images by a Monte Carlo simulation method.
The image reconstruction was performed by means of the proposed two methods, in which OS-EM algorithm is modified with the estimated DRF. Method-1 is the OS-EM algorithm incorporating DRF into forward projection. Method-2 is the OS-EM algorithm incorporating DRF into forward and back projection. The DRF is estimated from projection data of eight point sources at different distance from the center. We have evaluated quantitatively our methods for point sources and the brain phantom generated by using a Monte Carlo simulation method.
Applying our methods to the simulation studies for point sources and the brain phantom, the in-plane resolution at the point far from the center found to be improved without complex calculation and special hardware.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 BrainPET'03
発表年月日
日付 2003-07-03
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:38:08.601457
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3