ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Induction of Micronuclei in a Rat Alveolar Epithelial Cell Line by Alpha Particle Irradiation

https://repo.qst.go.jp/records/67299
https://repo.qst.go.jp/records/67299
ddd757ab-5969-4cf7-98c0-364487e83aad
Item type 会議発表用資料 / Presentation(1)
公開日 2002-12-13
タイトル
タイトル Induction of Micronuclei in a Rat Alveolar Epithelial Cell Line by Alpha Particle Irradiation
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Yamada, Yutaka

× Yamada, Yutaka

WEKO 661627

Yamada, Yutaka

Search repository
Oghiso, Yoichi

× Oghiso, Yoichi

WEKO 661628

Oghiso, Yoichi

Search repository
Enomoto, Hiroko

× Enomoto, Hiroko

WEKO 661629

Enomoto, Hiroko

Search repository
Ishigure, Nobuhito

× Ishigure, Nobuhito

WEKO 661630

Ishigure, Nobuhito

Search repository
山田 裕

× 山田 裕

WEKO 661631

en 山田 裕

Search repository
小木曽 洋一

× 小木曽 洋一

WEKO 661632

en 小木曽 洋一

Search repository
榎本 宏子

× 榎本 宏子

WEKO 661633

en 榎本 宏子

Search repository
石榑 信人

× 石榑 信人

WEKO 661634

en 石榑 信人

Search repository
抄録
内容記述タイプ Abstract
内容記述 Dose-response relationships for the induction of micronuclei were characterised in the rat alveolar epithelial cell line (SV40T2) exposed to either alpha particles (241Am: 3.2 MeV, 128 keV.um-1, 0.093 Gy.min-1 at the cell-Mylar interface) or X rays (200 kVp, 1 Gy.min-1). The frequency of micronucleus formation was 1.6-3.0% for unirradiated subjects but increased for irradiated ones in a dose-dependent manner. A linear relationship between the dose and the micronucleus formation was observed until 1 Gy for alpha particles and 4 Gy for X rays. The linear slope for alpha particles was 28.5% per Gy and the relative biological effectiveness was 4.3 as calculated from the slopes. The slope for alpha particles was dependent on the energy of the alpha particles. These results indicate that the micronucleus assay is available for biodosimetry of alpha particle irradiation in the rat alveolar epithelial cells, although consideration should be given to the range of the linearity and the LET of alpha particles.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 13th Symposium on Microdosimetry
発表年月日
日付 2001-06-01
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:39:22.356981
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3