ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Registration of SPECT, PET and/or X-ray CT images in patients with lung cancer

https://repo.qst.go.jp/records/67287
https://repo.qst.go.jp/records/67287
d4abe54e-21b0-4325-badf-9e10e709530b
Item type 会議発表用資料 / Presentation(1)
公開日 2002-11-18
タイトル
タイトル Registration of SPECT, PET and/or X-ray CT images in patients with lung cancer
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Uemura, Koji

× Uemura, Koji

WEKO 661530

Uemura, Koji

Search repository
Toyama, Hinako

× Toyama, Hinako

WEKO 661531

Toyama, Hinako

Search repository
Miyamoto, Tadaaki

× Miyamoto, Tadaaki

WEKO 661532

Miyamoto, Tadaaki

Search repository
Mori, Yutaka

× Mori, Yutaka

WEKO 661533

Mori, Yutaka

Search repository
Yoshikawa, Kyosan

× Yoshikawa, Kyosan

WEKO 661534

Yoshikawa, Kyosan

Search repository
上村 幸司

× 上村 幸司

WEKO 661535

en 上村 幸司

Search repository
外山 比南子

× 外山 比南子

WEKO 661536

en 外山 比南子

Search repository
宮本 忠昭

× 宮本 忠昭

WEKO 661537

en 宮本 忠昭

Search repository
森 豊

× 森 豊

WEKO 661538

en 森 豊

Search repository
吉川 京燦

× 吉川 京燦

WEKO 661539

en 吉川 京燦

Search repository
抄録
内容記述タイプ Abstract
内容記述 Aim: In order to evaluate the therapeutic gain of heavy ion therapy performed on patients with lung cancer, the regional pulmonary functions and the amount of radio tracer accumulation to the tumor, we are investigated by using the region of interest based on anatomical information obtained from X-ray CT. There are many registration techniques for brain images, but not so much for the other organ images that we have studied registration of chest SPECT, PET and/or X-ray CT images.
Materials and Methods: Perfusion, ventilation and blood pool images with Tc99m labeled radiopharmaceuticals and SPECT, tumor images with 11C-methionine and PET and X-ray CT scans were performed on several patients with lung cancer before and after heavy ion therapy. The registrations of SPECT-CT, PET-CT and CT-CT were performed by using AMIR (Automatic Multimodality Image Registration), which was developed by Babak et al. for registration of brain images. In a case of SPECT-CT registration, each of the three functional images was registered to the X-ray CT image, and the accuracy of each registration was compared. In the studies of PET-CT registration, the transmission images and X-ray CT images were registered at first, because the 11C-methionine PET images bear little resemblance to the underlying anatomical images. Next, the emission images were realigned by using the same registration parameters. The X-ray CT images obtained from a single subject at the different time were registered to the first X-ray CT images, respectively.
Results: In the SPECT-CT registration, the blood pool-CT registration is the best among three SPECT images in visual inspection by radiologists. In the PET-CT registration, the Transmission-CT registrations got good results. Therefore, Emission-CT registrations also got good results. In the CT-CT registration, the X-ray CT images obtained from a single subject at the different time were superimposed well each other except for lower lobe. As the results, it was found to be possible to evaluate the therapeutic gain of heavy particle therapy sequentially by using the same ROI.
Conclusion: This method is useful for evaluating the therapeutic gain of heavy particle therapy performed on patients with lung cancer quantitatively and sequentially. Registration of chest SPECT, PET and/or X-ray CT images by using AMIR method got good result for all of the registrations.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 8th Congress of the World Federation of Nuclear Medicine & Biology
発表年月日
日付 2002-10-04
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:39:30.510187
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3