Simultaneous determination of ultra-trace level 237Np and Pu isotopes in soil/sediment samples by sector-field ICP-MS with a single-column chromatographic separation

https://repo.qst.go.jp/records/66914
https://repo.qst.go.jp/records/66914
759f8f1a-5698-4365-ae62-6cab51629390
Item type 会議発表用資料 / Presentation(1)
公開日 2018-09-18
タイトル
タイトル Simultaneous determination of ultra-trace level 237Np and Pu isotopes in soil/sediment samples by sector-field ICP-MS with a single-column chromatographic separation
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Huang, Zhaoya

× Huang, Zhaoya

WEKO 657836

Huang, Zhaoya

Search repository
Ni, Youyi

× Ni, Youyi

WEKO 657837

Ni, Youyi

Search repository
Wang, Hai

× Wang, Hai

WEKO 657838

Wang, Hai

Search repository
Zheng, Jian

× Zheng, Jian

WEKO 657839

Zheng, Jian

Search repository
Uchida, Shigeo

× Uchida, Shigeo

WEKO 657840

Uchida, Shigeo

Search repository
Sakaguchi, Aya

× Sakaguchi, Aya

WEKO 657841

Sakaguchi, Aya

Search repository
黄 召亜

× 黄 召亜

WEKO 657842

en 黄 召亜

Search repository
鄭 建

× 鄭 建

WEKO 657843

en 鄭 建

Search repository
内田 滋夫

× 内田 滋夫

WEKO 657844

en 内田 滋夫

Search repository
抄録
内容記述タイプ Abstract
内容記述 Introduction
237Np and Pu isotopes (239Pu and 240Pu) are regarded as highly radiological and biological toxic pollutants in the environment because of their alpha emission, long half-lives and readily enrichment in human bones and livers. These radionuclides were released into the environment by the nuclear weapon tests during the 1950s to 1980s. To assess the distribution and migration of 237Np and Pu isotopes, thus to evaluate their radiation impact in the environment, after nuclear accident, it is important to determine low level 237Np and Pu isotopes in environmental samples. This work presented a determination method of trace level 237Np and 239,240Pu in soil/sediment samples based on anion-exchange resin and SF-ICP-MS.
\nMethod
In this method, 0.57 pg of 242Pu was used as recovery tracer for both 237Np and Pu isotopes. A commercial anion-exchange resin AG MP-1M was used for the separation of Np and Pu from U, Th and other interferences. A SF-ICP-MS (Element XR, Thermo Scientific, Geermany) combined with an APEX-Q high efficiency sample introduction system (Elemental Scientific Inc, Omaha, NE, USA) was used for the analysis of 237Np and Pu isotopes. Prior to the analysis by SF-ICP-MS, three procedures were included for the sample preparation, a) HNO3-HF digestion; b) LaF3 and CaF2 co-precipitation and c) chromatographic separation. As the chemical behavior of Np and Pu were affected by their oxidation states, several often used reducing reagents (TiCl3, ascorbic acid+Fe2+, NH4OH•HCl and K2S2O5) were tested and their effects were compared.
\nResults and discussion
The chemical fractionation occurring between Np and Pu were evaluated by comparing their recovery. For 20 times of determination of 237Np and 242Pu added in deep soil, the ratio of their recovery, Recovery(237Np)/Recovery(242Pu) was 1.02±0.02, which proved that 242Pu can be used as a tracer for monitoring the recovery of 237Np in this method. For 0.2-4g sediment samples the obtained decontamination factor of 238U was 2.5×105~8.5×106. The 238U concentrations in the final sample solutions were below 5.1 pg/mL and no interference correction was needed for the analysis of 237Np and Pu isotopes. The chemical recovery for 242Pu was 79.6%. The instrument detection limits for 237Np, 239Pu and 240Pu were 0.11 fg/mL, 0.092 fg/mL and 0.14 fg/mL, respectively. The method detection limits for 237Np, 239Pu and 240Pu were 0.26 fg/g, 0.71 fg/g and 0.27 fg/g when 1g of soil/sediment was measured, respectively. To demonstrate the accuracy of our method, 237Np and 239,240Pu concentrations in several standard reference materials were determined. The results showed good consistency with the certificated values and the reported values. The high decontamination factor of 238U, together with the low LODs and the chemical recovery of 79.6% demonstrated the ability of this method for the determination of utral-trace level of Np and Pu isotopes in soil/sediment samples.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 日本分析化学会第67年会
発表年月日
日付 2018-09-12
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:43:32.728678
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3