ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

Contribution to dose in healthy tissue from secondary target fragments in therapeutic proton, He and C beams measured with CR-39 plastic nuclear track detectors

https://repo.qst.go.jp/records/66896
https://repo.qst.go.jp/records/66896
3e3b0dde-4aea-4093-98fd-403f351132e5
Item type 会議発表用資料 / Presentation(1)
公開日 2018-09-10
タイトル
タイトル Contribution to dose in healthy tissue from secondary target fragments in therapeutic proton, He and C beams measured with CR-39 plastic nuclear track detectors
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 小平, 聡

× 小平, 聡

WEKO 657703

小平, 聡

Search repository
小平 聡

× 小平 聡

WEKO 657704

en 小平 聡

Search repository
抄録
内容記述タイプ Abstract
内容記述 The LET spectrum, absorbed dose and dose equivalent from secondary particles of LET_H2O ≥15 keV/µm deposited within the plateau of the Bragg curve in primary particle-induced nuclear target fragmentation reactions in tissue during proton and heavy ion radiotherapy were measured using CR-39 plastic nuclear track detectors and analyzed by means of atomic force microscopy. It was found that secondary target fragments contributed 20% to dose equivalent for primary protons (157 MeV), 13% for primary helium ions (145 MeV/n) and 4% for primary carbon ions (383 MeV/n), respectively. While this additional dose is currently not considered in any standard treatment planning software, such contributions to dose to healthy tissue are significant from the point of view of patient radiation safety. The smaller contribution measured for energetic carbon ion beams compared to proton beams can be considered an advantage of carbon ion radiotherapy over proton radiotherapy. This type of measurement is not only relevant to radiation protection in cancer therapy, but also in space radiation dosimetry and protection, since 99% of the space radiation environment consists of energetic protons and helium nuclei. Some verification of secondary particles with CR-39 were reported by measuring stopping particles in the detector. The type of ground-based experiment reported here are useful for investigating the dose contribution of secondary target fragmentation produced by space radiation to the absorbed dose and dose equivalent received by space crews.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 23th WRMISS(Workshop on Radiation Monitoring for the International Space Station)における口頭発表
発表年月日
日付 2018-09-06
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:43:43.926126
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3